»   Categories   »   EMI

EMI


Filter: 
A.H. Systems BCP-510 Broadband Current Probe 20 Hz – 1 MHz
A.H. Systems BCP-510 Broadband Current Probe 20 Hz – 1 MHz
Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on current probes. The BCP-510 Current Probe is designed to permit field intensity meters, spectrum analyzers, and other ... View Details >>
A.H. Systems BCP-512 Broadband Current Probe 1 MHz – 1000 MHz
A.H. Systems BCP-512 Broadband Current Probe 1 MHz – 1000 MHz
Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on current probes. The BCP-512 Current Probe is designed to permit field intensity meters, spectrum analyzers, and other ... View Details >>
A.H. Systems BCP-514 Broadband Current Probe 10 kHz – 100 MHz
A.H. Systems BCP-514 Broadband Current Probe 10 kHz – 100 MHz
The BCP-514 measures high power pulse currents such as those associated with EMP wave shapes. This current probe is designed to clamp around large conductors or bundles of wire with an aperture of 70 mm.... View Details >>
A.H. Systems BCP-516 Broadband Current Probe 10 kHz – 50 MHz
A.H. Systems BCP-516 Broadband Current Probe 10 kHz – 50 MHz
The BCP-516 is used to measure conducted emissions from 10 KHz to 50 MHz It has a usable frequency range of 10 Hz to 70 MHz This broadband current probe has a transfer impedance of 8 dBW (± 4 dB) from 30 KHz to 50 MHz The BCP-516 current probe... View Details >>
A.H. Systems BCP-518 Broadband Current Probe 100 kHz – 500 MHz
A.H. Systems BCP-518 Broadband Current Probe 100 kHz – 500 MHz
For ease and convenience of performing conducted measurements, all of our Current Probes utilize the split type clamp-on design. The BCP-518 is ideally suited to measuring currents for the immunity requirements of DO-160 and IEC-1000-4-6 on large cab... View Details >>
A.H. Systems BCP-519 Broadband Current Probe 100 Hz – 500 MHz
A.H. Systems BCP-519 Broadband Current Probe 100 Hz – 500 MHz
Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on current probes. The BCP-519 Current Probe is designed to permit field intensity meters, spectrum analyzers, and other ... View Details >>
A.H. Systems BCP-522 Broadband Current Probe 1 kHz – 200 MHz
A.H. Systems BCP-522 Broadband Current Probe 1 kHz – 200 MHz
This current probe is for laboratory and field testing where size is important. With a small outer diameter, approximately 71 mm with an internal diameter of 32 mm makes this current probe a powerful tool. The usable frequency range of the series is ... View Details >>
A.H. Systems BCP-526 Broadband Current Probe 1 kHz – 200 MHz
A.H. Systems BCP-526 Broadband Current Probe 1 kHz – 200 MHz
This current probe is for laboratory and field testing where size is important. With a small outer diameter, approximately 71 mm with an internal diameter of 32 mm makes this current probe a powerful tool. The usable frequency range of the series is ... View Details >>
A.H. Systems ECF-10 Equivalent Capacitive Fixture 100 Hz – 60 MHz
A.H. Systems ECF-10 Equivalent Capacitive Fixture 100 Hz – 60 MHz
The ECF-10 is a 10 pF capacitance fixture used for system checks and calibration of the active monopole antennas. One of the functions of the matching network is to convert the high impedance input of the antenna element to the 50 ohm impedance of th... View Details >>
A.H. Systems ICP-521 Current Injection Probe 10 kHz – 100 MHz
A.H. Systems ICP-521 Current Injection Probe 10 kHz – 100 MHz
The ICP-521 is low frequency injection current probe that can be used as pulse injection source as well as a sensitive monitoring probe. This probe can inductively couple transients having rise times as short as 5 nanoseconds and half pulse width dur... View Details >>
A.H. Systems ICP-522 Current Injection Probe 10 kHz – 400 MHz
A.H. Systems ICP-522 Current Injection Probe 10 kHz – 400 MHz
Injection Current Probes are used to inductively couple large RF currents into conductors passing through their aperture. The conductors are signal, control and power circuits of equipment under test for conducted susceptibility or immunity. This inj... View Details >>
A.H. Systems ICP-523 Current Injection Probe 300 kHz – 1000 MHz
A.H. Systems ICP-523 Current Injection Probe 300 kHz – 1000 MHz
This high frequency injection current probe is used for BCI testing in accordance with automotive specifications as well as diagnostic bulk current injection testing up to 1,300 MHz. The insertion loss is 7 dB or less from 1 MHz to 600 MHz and 11 dB ... View Details >>
Solar 2854-1 Transient Generator
Solar 2854-1 Transient Generator
For MIL-STD-461F CS106 Conducted Transient Susceptibility Test. The generator provides 5 μS ±22 %, pulse with a 1.5 μS ± 0.5 μS rise time across a 5.0 ohm non-inductive resistor. Voltage is adjustable to g... View Details >>
Solar 6550-1 Power Sweep Generator
Solar 6550-1 Power Sweep Generator
100 Watt Source For Conducted Audio Frequency Susceptibility Testing. A switch allows selection of triangular, square wave and sine wave shapes. The frequency range switch provides ten-to-one ranges from 15 Hz to 150 KHz in four steps. The calibra... View Details >>
Solar 7334-1 Loop Antenna
Solar 7334-1 Loop Antenna
For RE01 and RE101 Magnetic Emissions Tests. The Solar Type 7334-1 Loop Antenna has been designed as a substitute for the AT-205/URM-6 antenna and is a replacement for Eaton Model 94607-1. It uses 36 turns of wire on a 5.25" (13.3 cm) diamete... View Details >>
Solar 7399-2 Spike Generator 2500 Volts
Solar 7399-2 Spike Generator 2500 Volts
For Conducted Transient Susceptibility Testing. The Model 7399-2 Spike Generator is a “Big Bang” unit capable of providing high energy spikes with amplitudes adjustable up to 2500 volts; peak, into low impedance loads, as required by paragraph... View Details >>
Solar 7429-1 Loop Antenna
Solar 7429-1 Loop Antenna
For RS01 Magnetic Field Tests. The loop antenna used for generating radiated magnetic fields is fully described in Figure 1A of MIL-STD-461A. It consists of ten urns of number 16 A.W.G. wire on an insulated from 4.72" (12 cm) in diameter. The... View Details >>
Solar 8602 Line Impedance Stabilization Network (LISN)
Solar 8602 Line Impedance Stabilization Network (LISN)
The Solar Electronics LISNs use a series inductor between the test sample and the power source to provide the impedance-versus frequency characteristic. A coaxial connector with DC isolation is provided for connection to the associated frequency sele... View Details >>
Solar 8610 Line Impedance Stabilization Network (LISN)
Solar 8610 Line Impedance Stabilization Network (LISN)
The Solar Electronics LISNs use a series inductor between the test sample and the power source to provide the impedance-versus frequency characteristic. A coaxial connector with DC isolation is provided for connection to the associated frequency sele... View Details >>
Solar 8850-2 High Power Sweep Generator
Solar 8850-2 High Power Sweep Generator
For Conducted Audio Frequency Susceptibility Testing. The Model 8850-2 Power Sweep Generator provides audio power in a manually tuned or sweeping mode for four frequency bands covering 30 Hz to 150 KHz. The sweep rate is compliant with the require... View Details >>
Solar 9130-1 Loop Antenna
Solar 9130-1 Loop Antenna
For Receiving or Generating Magnetic Fields 10 kHz – 3 MHz This antenna was designed as a replacement for Eaton 94608-1. It is similar to Stoddart 91117-2, 30-inch diameter loop, supplied with AN/URM-6B and NM-10A EMI receivers. In addition to o... View Details >>
Solar 9230-1 Radiating Loop TYPE 9229-1 Loop Sensor
Solar 9230-1 Radiating Loop TYPE 9229-1 Loop Sensor
For MIL-STD-461D/RS101 Magnetic Field Tests. Test Method RS101 of MIL-STD-461D requires radiated magnetic fields over the frequency range 30 Hz to 100 KHz to determine the susceptibility or immunity of the equipment under test (EUT). Two loop ant... View Details >>
Solar 9335-2 Multiple Impedance Coupling Device
Solar 9335-2 Multiple Impedance Coupling Device
Impedance Matching Injection Probe. The unique winding arrangement of this impedance matching probe provides step-up or step-down ratios with respect to either: 1) the source impedance of the connected generator, when used for injection, or 2) the... View Details >>
Solar 9354-1 Transient Generator
Solar 9354-1 Transient Generator
For Susceptibility Tests MIL-STD461C/D/E and Other Specifications. The Model 9354-1 & 9354-2 Transient Generators provide nine selectable waveforms, including six damped sinusoidal pulses (10 KHz,100 KHz, 1 MHz, 10 MHz, 30 MHz, and 100 MHz) a... View Details >>
Solar 9354-2 Transient Generator
Solar 9354-2 Transient Generator
For Susceptibility Tests MIL-STD461C/D/E and Other Specifications. The Model 9354-1 & 9354-2 Transient Generators provide nine selectable waveforms, including six damped sinusoidal pulses (10 KHz,100 KHz, 1 MHz, 10 MHz, 30 MHz, and 100 MHz) a... View Details >>
Solar 9355-1 Pulse Generator
Solar 9355-1 Pulse Generator
For MIL-STD461D/E CS115 Susceptibility Test. The charged line potential of the Model 9355-1 is adjustable from less than 2 volts to greater than 2000 volts. The repetition rate is variable from less than 0.6 p.p.s. to greater than 150 p.p.s., or s... View Details >>
Solar Model 6254-5S RFI Transient Generator
Solar Model 6254-5S RFI Transient Generator
For Conducted Transient Susceptibility Testing Up to 250 volts, peak The Model 6254-5S RFI Transient Generator provides up to 250 volts peak amplitude. The output transient shape follows the curve given in Figure 19 of MIL-STD-462. Less than 1.0 m... View Details >>
Solar RFI/EMI Current Probes and Injection Probes
Solar RFI/EMI Current Probes and Injection Probes
Current probes required by various EMI specifications (such as MIL-STD-461/2) are toroidal transformers designed to measure r.f. currents on active power lines or other conductors. Direct connection to the conductor carrying EMI current is not nec... View Details >>

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E