Description

For Conducted Transient Susceptibility Testing Up to 250 volts, peak

The Model 6254-5S RFI Transient Generator provides up to 250 volts peak amplitude. The output transient shape follows the curve given in Figure 19 of MIL-STD-462. Less than 1.0 microsecond rise time, falling to zero in 8 to 14 microseconds, crossing through zero to ring in the manner of an inductive transient and returning to zero again as it rings. The amplitude of the transient is adjustable from less than 10 volts to over 250 volts peak.

Using series injection on 50, 60 or 400 Hz lines, the transient can be applied to the positive or the negative half-cycle. The transients relation to the sine wave may be adjusted in phase from 0° to 360°.

For non-synchronous injection, the repetitive rate of the transient can be adjusted from 0.5 to 500 p.p.s.

For synchronous injection, a square wave input from an external source enables the transient to be triggered in terms of the digital or pulse characteristics of the test sample through the range 0.1 p.p.s. to 800 p.p.s.

A panel mounted push-button allows manual injection of single transients. A rear connector provides for remote triggering of single transients in terms of your system requirements.

Output terminals provide for either series injection on AC. lines or parallel injection on DC lines as required by specifications. Output terminals are isolated from chassis and the AC line.

Features

  • Provides outputs from less than
    10 volts to over 250 volts peak amplitude into high impedance loads and more than 35 kw into 0.5 ohm load.
  • Wider range of repetition rates allows greater utilization in empirical setups.
  • Output terminals for series or parallel injection.
  • Single pulse feature enables controlled isolation of transient effects.
  • Adjustable pulse position on AC lines relates the transient susceptibility to the real time aspects of digital systems.
  • Transient may be injected in synchronism with repetitive circuit functions as required by method CS06 of MIL-STD-462.
  • Remote triggering of individual or repetitive pulses in terms of particular system characteristics.

 Solar 6254-5S Applications

The Model 6254-5S RFI Transient Generator was especially designed for screen room use in making conducted transient susceptibility tests as required by military specifications. These specifications include: parts of MIL-STD-461A/462, MSFC-STD-279, Lockheed 422966 (L1011), TRW TOR-1001,Douglas WZZ-7000 (DC-10), and others.

Specifications

Spike Amplitude

Continuously adjustable from less than 10 volts to more than 250 volts peak.

Repetition Rate

Continuously adjustable from 0.5 to 500 p.p.s.

Rise Time

Less than 1.0 microsecond.

Spike Duration

Output falls to zero in approximately 8 to 14 microseconds.

Spike Shape

Ringing characteristic as shown in Figure 19 of MIL-STD-462.

Phase Adjustment

Spike position adjustable from 0° to 360° on 50, 60
or 400 Hz lines.  

Sync Operation

Triggers at any rate from once every ten seconds to over 800 transients per second.

Internal Impedance

0.5 ohm.

Output Power

More than 35 kw peak into 0.5 ohm load.

Power Current in Series Injection Mode

Handles up to 50 amperes at power frequencies.

Power Requirements

115 volts 60 Hz, 1.8 amperes. (230 volts 50 Hz, 0.9 ampere available.)

Dimensions

8.125" wide, 9" high, 14.625" deep. (20.64 cm x 22.86 cm x 37.15 cm.)

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E