A.H. Systems BCP-510 Broadband Current Probe 20 Hz – 1 MHz
A.H. Systems BCP-510 Broadband Current Probe 20 Hz – 1 MHz
Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on current probes. The BCP-510 Current Probe is designed to permit field intensity meters, spectrum analyzers, and other ... View Details >>
A.H. Systems BCP-511 Broadband Current Probe 20 kHz – 100 MHz
A.H. Systems BCP-511 Broadband Current Probe 20 kHz – 100 MHz
Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on current probes. The BCP-511 Current Probe is designed to permit field intensity meters, spectrum analyzers, and other ... View Details >>
A.H. Systems BCP-512 Broadband Current Probe 1 MHz – 1000 MHz
A.H. Systems BCP-512 Broadband Current Probe 1 MHz – 1000 MHz
Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on current probes. The BCP-512 Current Probe is designed to permit field intensity meters, spectrum analyzers, and other ... View Details >>
A.H. Systems BCP-514 Broadband Current Probe 10 kHz – 100 MHz
A.H. Systems BCP-514 Broadband Current Probe 10 kHz – 100 MHz
The BCP-514 measures high power pulse currents such as those associated with EMP wave shapes. This current probe is designed to clamp around large conductors or bundles of wire with an aperture of 70 mm.... View Details >>
A.H. Systems BCP-515 Broadband Current Probe 1 MHz – 400 MHz
A.H. Systems BCP-515 Broadband Current Probe 1 MHz – 400 MHz
This current probe can operate without saturation from 300 amperes of DC to 400 Hz, 50 amperes of pulse current and 20 amperes of CW.... View Details >>
A.H. Systems BCP-516 Broadband Current Probe 10 kHz – 50 MHz
A.H. Systems BCP-516 Broadband Current Probe 10 kHz – 50 MHz
The BCP-516 is used to measure conducted emissions from 10 KHz to 50 MHz It has a usable frequency range of 10 Hz to 70 MHz This broadband current probe has a transfer impedance of 8 dBW (± 4 dB) from 30 KHz to 50 MHz The BCP-516 current probe... View Details >>
A.H. Systems BCP-518 Broadband Current Probe 100 kHz – 500 MHz
A.H. Systems BCP-518 Broadband Current Probe 100 kHz – 500 MHz
For ease and convenience of performing conducted measurements, all of our Current Probes utilize the split type clamp-on design. The BCP-518 is ideally suited to measuring currents for the immunity requirements of DO-160 and IEC-1000-4-6 on large cab... View Details >>
A.H. Systems BCP-519 Broadband Current Probe 100 Hz – 500 MHz
A.H. Systems BCP-519 Broadband Current Probe 100 Hz – 500 MHz
Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on current probes. The BCP-519 Current Probe is designed to permit field intensity meters, spectrum analyzers, and other ... View Details >>
A.H. Systems BCP-522 Broadband Current Probe 1 kHz – 200 MHz
A.H. Systems BCP-522 Broadband Current Probe 1 kHz – 200 MHz
This current probe is for laboratory and field testing where size is important. With a small outer diameter, approximately 71 mm with an internal diameter of 32 mm makes this current probe a powerful tool. The usable frequency range of the series is ... View Details >>
A.H. Systems BCP-526 Broadband Current Probe 1 kHz – 200 MHz
A.H. Systems BCP-526 Broadband Current Probe 1 kHz – 200 MHz
This current probe is for laboratory and field testing where size is important. With a small outer diameter, approximately 71 mm with an internal diameter of 32 mm makes this current probe a powerful tool. The usable frequency range of the series is ... View Details >>
A.H. Systems BCP-620 Broadband Current Probe 10 kHz – 500 MHz
A.H. Systems BCP-620 Broadband Current Probe 10 kHz – 500 MHz
This current probe can handle 100 amperes of pulse currents and 50 amperes of CW between the usable frequency range of 10 kHz to 500 MHz.... View Details >>
A.H. Systems ECF-10 Equivalent Capacitive Fixture 100 Hz – 60 MHz
A.H. Systems ECF-10 Equivalent Capacitive Fixture 100 Hz – 60 MHz
The ECF-10 is a 10 pF capacitance fixture used for system checks and calibration of the active monopole antennas. One of the functions of the matching network is to convert the high impedance input of the antenna element to the 50 ohm impedance of th... View Details >>
Solar RFI/EMI Current Probes and Injection Probes
Solar RFI/EMI Current Probes and Injection Probes
Current probes required by various EMI specifications (such as MIL-STD-461/2) are toroidal transformers designed to measure r.f. currents on active power lines or other conductors. Direct connection to the conductor carrying EMI current is not nec... View Details >>
TESEQ CSP 9160 EMC Emission/Immunity Sensing Probe
TESEQ CSP 9160 EMC Emission/Immunity Sensing Probe
The CSP 9160 is a broadband RF current sensor probe as defined in CISPR 16-1-2. Beside the compliance measurements of asymmetrical disturbance currents as e.g. required in CISPR 16-2-1 and CISPR 22, the probe can be used in a number of diagnostic app... View Details >>
TESEQ MD 300 Surge Pulse Current Probe Set
TESEQ MD 300 Surge Pulse Current Probe Set
The MD 300 probe has been specially designed to verify surge current pulses as specified in IEC/EN 61000-4-5, ANSI C62.41 and their derivates. The main advantage of the MD 300 current probe is, that the measuring system is physically isolated from... View Details >>
TESEQ MD 4070 Monitoring Device 10 kHz – 400 (600) MHz
TESEQ MD 4070 Monitoring Device 10 kHz – 400 (600) MHz
The monitoring device MD 4070 can be used as an active or passive current sensor probe to measure the current in a conductor without connecting it directly. The MD 4070 allows fast and easy measurement as it can be quickly clamped around the current ... View Details >>

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E