»  Categories   »      Programmable Supply   »    Three Phase Power   »    DC Power Supply   »    AC Power Supply   »    Power Supply   »    Mains Dips & Drops   »    Harmonics & Flicker   »    Dips & Interrupts  

image enlarge

TESEQ NSG 1007-5 Programmable AC & DC Power Source 5kVA

Description

The NSG 1007 series sources are microprocessor controlled and can be operated from an easy to use front panel keypad. Functions are grouped logically and are directly accessible from the keypad. This eliminates the need to search through various levels of menus and/or soft keys. A large analogue control knob can be used to quickly slew output parameters. This knob is controlled by a dynamic rate change algorithm that combines the benefits of precise control over small parameter changes with quick sweeps through the entire range.

By combining a flexible AC/DC power source with a high performance power analyzer, the Teseq NSG 1007 sources are capable of handling complex applications that have traditionally required multiple instruments.

With a crest factor of up to 5:1, the NSG 1007 series sources can drive difficult nonlinear loads with ease. Since many modern products use switching power supplies, they have a tendency to draw high repetitive peak currents. The Teseq sources can deliver a repetitive peak current of up to 3 times their rated continuous current.

With precise output regulation and accuracy, the sources address many application areas for AC and DC power testing. They provide a high load current capability, multi or single phase output modes, and built-in power analyzer measurements. Additional features including line distortion simulation (LDS), arbitrary waveform generation, and programmable output impedance address requirements for product quality and regulatory compliance testing.

Features

  • Combination AC and DC power
  • Source and power analyzer
  • Arbitrary waveform generation
  • Built-in digital power analyzer
  • Meets source requirements for
  • IEC 61000-3-2 and -3-3

Specifications

Model

NSG 1007-3

NSG 1007-5

NSG 1007-10

NSG 1007-15

Supply option

240

208

400

208

400

208

400

Operating modes

AC, DC, or AC + DC

Frequency range

16 Hz – 1000 Hz (See voltage de-rating Vs frequency chart below)

Total power

3,000 VA

5,000 VA

10,000 VA

15,000 VA

Load power factor

0–1 at full rated power

AC mode voltage

Voltage range

Low                             High

AC

0–150 V                      0–300 V

AC + DC

0–150 V                      0–300 V

Load regulation (ALC ON)

<0.2%    <0.2%

Load regulation (ALC OFF)

<0.5% DC–100 Hz    0.5% DC–100 Hz

 

<2.2% 100–500 Hz   <0.6% 100–500 Hz

 

<3% 500–1000 Hz     <3% 500–1000 Hz

Line regulation

     <0.1% for 10% line change

Output noise

(20 kHz to 1 MHz) <250 mVrms typical, <500 mVrms maximum

Harmonic distortion

<1% from 16-66 Hz, <2% at 400 Hz, <3% at 800 Hz

DC offset

<20 mV

External amplitude modulation

Depth 0-10%, Frequency DC-2 kHz

Isolation voltage

300 Vrms output to chassis

AC mode current

Maximum current per phase

Low range Steady state

22.2

37.0

74

37.0

Low range Peak repetitive

110.0

110.0

220.0

110

High range steady state

11.1

18.5

37.0

18.5

High range peak repetive

96.0

96.0

192.0

96.0

Programming accuracy

Voltage (rms) Frequency Current  limit Phase

±0.2% of range

±0.01% of programmed value

±0.5% of programmed value

<1.5° with balanced load at 50/60 Hz

Programming resolution

Voltage (rms) Frequency Current  limit Phase

100 mV

0.01 Hz 16–81.91 Hz, 0.1 Hz 82.0–819.1 Hz, 1 Hz 820–1000 Hz

0.1 Amps

0.1°

Output relay

Push-button controlled or bus controlled output relay

Output impedance

Programmable Z on NSG 1007-3, NSG 1007-5, NSG 1007-15

Resistive

Range: 17-1000 mOhm, Resolution: 4 mOhm, Accuracy: 2% FS

Inductive

Range: 230-1000 µH, Resolution: 4 µH, Accuracy 2% FS

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E