A diagnostic tool kit for use in both electrical and mechanical environments featuring three hand held probes (two magnetic, one electric) covering the frequency range 9 kHz to 1 GHz together with a 30 dB pre-amplifier, power adaptor and check jig. When used in conjunction with a spectrum analyzer or measuring receiver, the probes will readily locate and qualify sources of EMI (electromagnetic interference).
The two magnetic probes incorporate a high degree of rejection of both stray and direct electric fields - a frequent cause of measurement errors - providing far greater repeatability than with conventional loop field probes. The electric probe with built-in pre-amplifier is powered by the CPS 9753 power supply unit (supplied) via the CPS 9752 power adaptor.
- Locate emission “hot-spots”
- Check on mechanical screening performance
- Isolate faulty components
Teseq NFPS 1 Applications
- Shielded effectiveness comparisons
- Radiated field predictions
- Localized immunity tests on cables and components
- Diagnose poor bonding
MFP 9150
|
Magnetic Field Probe
|
Specified frequency range
|
9kHz - 30MHz
|
Connector
|
50Ω SMA Female
|
Max. RF power input
|
0.5 Watt
|
Size (Incl. RF connector)
|
256 x 38 x 18mm
|
Operating temperature
|
0 - 45°C
|
MFP 9151
|
Magnetic Field Probe
|
Specified frequency range
|
30MHz - 1GHz
|
Connector
|
50Ω SMA Female
|
Max. RF power input
|
0.25 Watt
|
Size (Incl. RF connector)
|
256 x 38 x 18mm
|
Size (Incl. RF connector)
|
x 0 - 45°C
|
EFP 9152
|
Electric Field Probe
|
Frequency range (±3dB)
|
9kHz - 1GHz
|
Antenna factor
|
67dB[(mV/m) /mV]
|
Connector
|
SMA Female
|
Size (Incl. RF connector)
|
267 x 38 x 18mm
|
PCJ 9251
|
Check Jig
|
Connector
|
N (Male)
|
Connector
|
Ix 50Ω
|
Max. RF power input
|
+20dBm
|
CPA 9231A
|
Pre-amplifier
|
Frequency range
|
9kHz - 2GHz
|
Noise figure
|
≤ 4dB
|
Input connector
|
N (Female)
|
Output connector
|
N (Male)
|
Gain
|
30dB ± 2dB at 1GHz
18dB at 2GHz
|
Input/ output impedance
|
50Ω
|
Input VSWR
|
< 2:1
|
Power requirements
|
15V ± 10% DC or
|
With probe)
|
(10V ± 0.1V DC at 100mA
|
CPS 9752
|
Power Adaptor
|
Power requirements
|
15V ± 1.5V dc
|
(With probe)
|
or 10V ± 0.1V dc
|
RF input connector
|
BNC (Female)
|
RF output connector
|
N (Male)
|
Size (Incl. RF connectors)
|
103 x 26 x 27mm
|
Standards
CISPR 11 |
CISPR 14 - 1 |
CISPR 14 - 2 |
CISPR 14 - 2 |
CISPR 16 - 1 |
CISPR 16 - 2 |
CISPR 16 - 3 |
CISPR 16 - 4 |
CISPR 22 |
CISPR 24 |
IEC/TR EN 61000 - 1 - 1 |
IEC/TR EN 61000 - 2 - 1 |
IEC/TR EN 61000 - 2 - 3 |
IEC EN 61000 - 3 - 2 |
IEC EN 61000 - 3 - 4 |
IEC/TC EN 61000 - 3 - 5 |
IEC EN 61000 - 4 - 2 |
IEC EN 61000 - 4 - 3 |
IEC EN 61000 - 4 - 4 |
IEC EN 61000 - 4 - 5 |
IEC EN 61000 - 4 - 6 |
IEC EN 61000 - 4 - 7 |
IEC EN 61000 - 4 - 8 |
IEC EN 61000 - 4 - 9 |
IEC EN 61000 - 4 - 11 |
EN 50 081 part 1 |
EN 50 081 part 2 |
EN 55 011 |
EN 55 013 |
EN 55 014 |
EN 55 015 |
EN 55 020 |
EN 55 022 |
EN 55 024 |
EN 50 082 part 1 |
EN 50 082 part 2 |
EN 50 093 |
FCC Part 15 |
MIL-STD - 461E |
|