»  Categories   »      CDN   »    EMC / EMI   »    Coupling / Decoupling (CDN)  

image enlarge

TESEQ CDN 3425 Burst/EFT Capacitive Coupling Clamp

Description

The CDN 3425 is Teseq’s newly designed Burst EFT coupling clamp. It replaces the earlier models CDN 8014 and CDN 8015.

The CDN 3425’s main purpose is to couple Burst/EFT pulses to data lines. It can also be used to couple to mains lines where no CDN is available; for example, high current lines >200 A.

This new design is fully compliant with the specifications of IEC 61000-4-4 Ed 2.0 2004, as well as with the draft of IEC 61000-4-4 Ed 3.0 to be published in 2012.

An INA 3425 calibration kit as specified in IEC 61000-4-4 Ed 3.0 2012 is available as an option. An optional INA 3825 safety cover with interlock function to be connected to NSG 3000 series generators is also available.

Features

  • New design
  • Complies with IEC 61000-4-4 Ed 2.0 2004
  • Complies with IEC 61000-4-4 Ed 3.0 2012
  • Safety cover with interlock
  • Calibration kit per IEC 61000-4-4 Ed 3.0 2012

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E