»  Categories   »      CDN   »    EMC / EMI   »    Coupling / Decoupling (CDN)  

image enlarge

TESEQ CDN 3083 B200 Manual Coupling/Decoupling Network

Description

The CDN 3083-B200 is a 3-phase burst pulse coupling decoupling network intended to allow EFT/Burst testing of equipment requiring large currents, specially designed for heavy industry, smart grid and electro vehicle applications.

The CDN 3083-B200 serves to inject fast transients (burst pulses) up to 8 kV (5/50 ns 50 Ω) into the supply lines of the Equipment Under Test.

The CDN 3083-B200 is designed to be used with an EUT supply in AC mode up to 690 V in line to line or line to ground. DC voltage can be taken up to 1000 V line to line or line to ground.
Although designed for continuous duty at up to 200 A per phase, the unit can be subjected to considerably higher currents for short durations.

High inrush currents or pulse-shaped peak currents can be handled with ease. The current limitation is largely a matter of thermal loading and ambient temperature. A built-in thermometer enables the heating effect to be monitored.

Its small and compact design allows easy handling and comfortable setup possibilities in standard compliant application setups, where distances between CDN and EUT are specified quiet short, and where the use of combined CDNs generally built in 19 racks show difficulties in meeting the test setup requirements specified by the standards.

Features

  • Compliant with IEC 61000-4-4
  • Up to 200 A AC or DC
  • Up to 690 VAC
  • Up to 1000 VDC
  • Large overstress capability
  • Easy handling and integration in
  • test setup
  • Compatible with all brands of
  • burst generators

Specifications

Parameter

Value

EUT voltage: 690 V AC RMS

1000 VDC

EUT current

≥200 A continuous

The maximum permissible current is given by the heat dissipated in the coupler. As the temperature is monitored, the CDN 3043-S200 can be heavily overloaded until the temperature reaches 70° C

Burst voltage

Max. 8800 V

Terminals

Screw terminals, rated for 200 A

Temperature monitoring

Bimetal-thermometer 0 to +120° C

Grounding

Earth terminal

4 mm combined banana

housing bottom direct to ground

plane via housing bottom plate and brackets

Size

430 x 310 x 190 mm

Weight

11 kg approx.

EFT/burst connector

SHV

Temperature range

Operation

+10 to +40°C

Storage

30 to +70% (non condensing)

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E