»  Categories   »      Absorbing Clamp   »    EMC / EMI  
   »  Brands   »  TESEQ   »  TESEQ AMZ 41 Absorbing Clamp

image enlarge

TESEQ AMZ 41 Absorbing Clamp

Description

The absorbing clamp AMZ 41 has been designed for measurement of radio interferences emitted from electrical instruments via their connecting leads. The absorbing clamp measurement method (ACMM) is described in Clause 7 of CISPR 16-2-2. The absorbing clamp itself is described in CISPR 16 part 1-3: Radio disturbance and immunity measuring apparatus – Ancillary equipment – Disturbance power.

Features

  • As specified in CISPR 16-1-3
  • Disturbance power measuring, according to CISPR 16-2-2
  • Can be used as a diagnostic tool
  • Measurement of screening attenuation of coaxial cables

Specifications

Parameter

Value

Parameter text

30 MHz to 1000 MHz

Min. site attenuation

13 dB to 22 dB

Clamp factor (CF)

-4 dB to +5 dB

Decoupling factor DF

>21 dB

Decoupling factor DR

>30 dB

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E