»  Categories   »      Benchtop Test Chamber   »    Environmental Chamber   »    Environmental   »    Chamber / Oven  

image enlarge

Tenney Benchmaster Test Chamber -73°C to 200°C

Description

Benchmaster Temperature and Humidity Test Chambers

Tenney's Benchmaster temperature and humidity test chambers are capable of simulating a wide range of temperature or temperature and humidity conditions. The five cubic foot work space will readily accept equipment as large as a 19"relay rack.

In keeping with the needs of today's lab, Tenney designed these temperature and humidity test chambers to have a compact exterior that maximizes the interior workspace.

Features

  • Vapor-tight interior liners of 100% continuously welded stainless steel
  • Humidity capable models constructed of 100% non-corroding parts and have a low-water protection system
  • Open-air low mass nichrome wire heating elements
  • Single stage or cascade refrigeration system with hermetic or semi-hermetic compressor
  • Capillary tube type refrigerant control
  • 100 Ohm Platinum RTD sensor for temperature measurement
  • Vapor-Flo I Humidity Generator (in humidity models)
  • Dry capacitance type humidity sensor
  • Hi-lo pressure and oil pressure switches
  • Chamber drain connection
  • Propeller type fans or blower wheels for airflow

Controller – Watlow F4

  • Single Channel
  • Profiling: Forty Profiles, 256 Steps
  • Automatic & Manual Control
  • 1 Input: Universal Type (RTD is Std.)
  • 4 Digital Inputs
  • 2 Auxiliary Analog Inputs - Optional
  • 2 Control Outputs: Time Proportioned, On/Off, or 4-20 ma
  • 2 Alarm Outputs
  • 8 Digital Event Outputs
  • 2 Retransmit Outputs - Optional
  • Communications: EIA-232 and EIA-485 with Modbus RTU protocol

Specifications

Overall dimensions in inches/mm

Model

BTC

BTRC

Workspace

W

20/51

D

19.25/49

H

22/56

Exterior

W

57/145

62/157

D

34/86

H

34.5/88

Low

C

-70

High

C

+200

Humidity Capability Utilities, etc

20% to 95% RH in the dry bulb range of +20C to +85C as limited by a 3 dewpoint.

Refrigeration

(2) 1 HP

Heater Capacity

2 kW

Humidifier

Watts

 

750

GPH

 

0.3

Amps@230V / 1 Ph

24

24

Amps Fuse

35

Unit Weight

LBS

500

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E