»  Categories   »      LCR Meter   »    Meter  

image enlarge

Keysight E4916A Crystal Impedance / LCR Meter

Description

Keysight E4916A is a crystal impedance meter based on the transmission network method which enables you to:
- Test at high frequencies (1 MHz to 180 MHz)
- Apply low drive level (0.1 nW to 1 mW, when testing a 25 ohm DUT with the circuit).

The Keysight E4916A yet provides a cost effective solution, comparable enough to conventional CI meters.

In addition to Fr and CI measurements, the Keysight E4916A offers a variety of testing capabilities including the equivalent circuit analysis and the drive level dependency characteristic evaluation (DLD) through easy-to- follow steps. It comes with the Keysight-IB and parallel I/O interfaces for easy connection to external equipment, thus allowing an automatic testing system to be configured.

Features

  • Based on the transmission network method recommended by the IEC444 standard.
  • Wide frequency range (1 MHz to 180 MHz)
  • Easy to change the drive level (nW to 1 mW)
  • Applies up to 20 mW to the DUT when used in combination with the optional impedance probe (option 001)
  • Allows you to use the same test
  • Fixtures as those for the network analyzer.
  • Provides the calibration to correct errors resulting from the extension of the cable.
  • Saves and recalls up to 10 patterns of the system settings together with calibration data

Specifications

Measurement parameters

 Fr, Fs, Fa, FL, CI, Q, C0, C1, L1, R1, R0, G0, spurious, DLD, EM, filter bandwidth (Note that Fr and Fs represent the frequencies at which the phase is 0 degree and the maximum conductance is attained, respectively. You can also set up the HP E4916A to search for Fr at which |Z| is minimal.)

Output Frequency range

1 MHz to 180 MHz/ 1 mHz resolution

Frequency accuracy

2 ppm (can be improved up to 0.2 ppm through external reference input)

Inputs (typical)

Measurement range

1 MHz to 180 MHz/1 mHz resolution

Impedance

5 to 125 W/10 mW resolution

Return loss

20 dB

Max. input level

0 dBm

Damage level

25 Vdc, 20 dBm

Average noise level

-130 dBm/Hz

Cross talk

-100 dB

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E