»  Categories   »      LCR Meter   »    Meter  

image enlarge

HP / Agilent 4263A LCR Meter

Description

The Agilent 4263A LCR Meter was designed for both component evaluation on the production line and fundamental impedance testing for bench top applications. The Agilent 4263A has five test frequencies that allow you to simulate testing under the correct conditions: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz. An optional 20 kHz test frequency can be added to those five frequencies.

The HP 4263A can boost throughput with a measurement speed of 25 ms at any test frequency. This ability improves the throughput of electrolytic capacitor and transformer testing. The 4263A LCR Meter can check the contact condition between the test terminals and the device under test (DUT). This function ensures the reliability of PASS/FAIL testing with automatic handlers in production. The quick recovery system of the 4263A improves throughput. Normal operation is resumed the instant a faulty DUT is removed from the handler, so the handler can always be operated at its full speed.

The Agilent 4263A's accuracy and wide measurement range are the right tools to make precise measurements of electrolytic capacitors. Charged capacitors can discharge through the front end and destroy an instrument. The front end of the 4263A was designed for protection and maintains test integrity.

With the 4263A's ability to make turns ratio (N), mutual inductance (M), and dc resistance (DCR) measurements, data calculations and changing test setups are no longer time-consuming tasks.

Features

  • 0.1% basic accuracy
  • 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz test frequencies
  • 20 m to 1 Vrms in 5m Vrms steps
  • Test signal level monitor function
  • High-speed measurement: 25 ms
  • High-speed contact check
  • Wide capacitance test range
  • Transformer parameter measurements (optional)

Specifications

High speed measurement

25 ms

High speed contact check

5 ms

Quick test recovery

Frontend protection

Built-in comparator

Handler interface

HP-IB interface

Cable length setting

0, 1, 2, and 4 meters

Eleven impedance parameters

100 Hz, 120 Hz, 1 kHz, 10 kHz, and 100 kHz test frequencies

50 mV, 100 mV, 250 mV, 500 mV, and 1 Vrms test levels

Wide capacitance test range

Transformer parameter (N/M/DCR) measurements (Option 001)

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E