Optimized for building envelope, restoration and remediation, inspection and roofing applications.

The Fluke TiR Thermal Imaging cameras are the perfect imagers for building envelope, restoration and remediation, inspection and roofing applications.

IR-Fusion® Technology
See things both ways-infrared and visual (visible light) images combined together communicating critical information faster and easier-traditional infrared images are no longer enough. The IR-Fusion is a patent-pending technology that simultaneously captures a digital photo in addition to the infrared image and combines it together, taking the mystery out of IR image analysis. IR-Fusion is standard on TiR models.

Features

  • Includes IR-Fusion® Technology both in camera and software (combines visible image with IR image in full screen or picture-in-picture views) for easy identification and reporting of problems
  • Rugged and reliable: Engineered to withstand a 2 m (6.5 ft) drop
  • 9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD
  • Temperature range and thermal sensitivity optimized for building diagnostics applications
  • Perfect for any application and budget
  • Excellent thermal sensitivity for seeing even small temperature differences (which could indicate problems)
  • Adjustable hand strap for left- or right-handed users
  • Manufactured in the U.S.A.

Specifications

Temperature performance

Calibrated temperature range

-20 °C to 150 °C (-4 °F to 302 °F)

Accuracy

±2 °C or 2 % (whichever is greater)

Measurement Modes

Smooth auto-scaling and manual scaling

Imaging performance

Field of view (FOV)

23º horizontal x 17º vertical

Spatial Resolution (IFOV)

2.5 mrad

Min. Focus Distance

Thermal lens: 15 cm (6 in)
Visible (visual) light lens: 46 cm (18 in)

Focus

Manual

Image Frequency

9Hz refresh rate

Detector type

160 X 120 focal plane array, uncooled microbolometer

Infrared lens type

20 mm F = 0.8 lens

Thermal Sensitivity (NETD)

≤ 0.09 °C at 30 °C target temp. (90 mK)

Infrared spectral band

7.5 μm to 14 μm

Visual camera

640 x 480 resolution

Image presentation

Palettes

Ironbow, blue-red, high contrast, grey

Level and span

Smooth auto-scaling and manual scaling of level and span

Minimum span (in manual mode)

2.5 C (4.5 °F)

Minimum span (in auto mode)
Fast Auto/Manual Range Toggle Fast Auto Rescale

5 °C (9 °F)

IR-Fusion® information

Full Infrared or Picture-in-Picture

Picture-In-Picture (PIP)

100 % IR displayed in center 320 x 240 pixels

Full screen (PIP off)

100 % IR displayed in center 640 x 480 LCD

Image and data storage

Storage medium

SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each or 3000 basic (.bmp) IR images

File formats

Non-radiometric (.bmp) or fully-radiometric (.is2) No analysis software required for non-radiometric (.bmp) files

Export file formats w/SmartView™ software

JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, and EMF

General Specifications

Operating Temperature

-10° C to 50° C (14° F to 122° F)

Storage Temperature

-20° C to +50° C (-4° C to 122° F)

Relative Humidity

10% to 90%, non-condensing

Display

9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD with backlight (selectable bright or auto)

Controls and adjustments

User selectable temperature scale (°C/°F)

Language selection

Time/date set

Software

SmartView™ full analysis and reporting software included

Battery

Internal rechargeable battery pack (included)

Battery life

3 to 4 hours continuous use (assumes 50 % brightness of LCD)

Battery charge time using ac adapter/charger or dc car charger

2 hours for full charge

AC operation/charging

AC adapter/charger (110 V ac to 220 V ac, 50 Hz to 60 Hz). Charges battery while imager is operating. Universal ac mains adapters included.

Power saving

Sleep mode activated after 5 minutes of inactivity, automatic power off after 30 minutes of inactivity

Safety standards

CE Directive: IEC/EN 61010-1 2nd Edition Pollution Degree 2

Electromagnetic compatibility

EMC directive: EN61326-1

C-Tick: IEC/EN 61326

US FCC: CFR 47, Part 15 Class A

Vibration

2 G, IEC 68-2-29

Shock

25 G, IEC 68-2-29 {2 m (6.5 ft) drop, 5 sides}

Dimensions (HxWxL)

0.27 m x 0.13 m x 0.15 m (10.5 in x 5 in x 6 in)

Weight

1.2 kg (2.65 lb)

IP rating

IP54

Warranty

Two-years

Calibration cycle

Two-years (assumes normal operation and normal aging)

Supported languages

English, Italian, German, Spanish, French, Russian, Portuguese, Swedish, Turkish, Czech, Polish, Finnish, Simplified Chinese, Traditional Chinese, Korean, and Japanese

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E