»  Categories   »      Thermal Imager   »    Environmental  
   »  Brands   »  Fluke   »  Fluke Ti25 Thermal Imager

image enlarge

Fluke Ti25 Thermal Imager

Description

The ultimate tools for troubleshooting and maintenance

This thermal Imager is the perfect tool to add to your problem solving arsenal. Built for tough work environments, this high-performance, fully radiometric infrared camera is ideal for troubleshooting electrical installations, electro-mechanical equipment, process equipment, HVAC/R equipment and others.

IR-Fusion Technology
See things both ways infrared and visual (visible light) images combined together communicating critical information faster and easier traditional infrared images are no longer enough. The IR-Fusion is a patent-pending technology that simultaneously captures a digital photo in addition to the infrared image and combines it together, taking the mystery out of IR image analysis. IR-Fusion is standard on Fluke Ti25.

Features

  • Enhanced problem detection and analysis capabilities with IR-Fusion® Technology. Simply scroll through the different viewing modes quickly to better identify trouble areas in Full IR thermal, picture-in-picture, or automatic blend visual and thermal images.
  • Optimized for field use in harsh work environments.
  • Engineered and tested to withstand a 2 m (6.5 ft) drop—when was the last time you dropped a tool?
  • Withstands dust and water—tested to an IP54 rating.
  • Delivers the clear, crisp images needed to find problems fast.
  • Identify even small temperature differences that could indicate problems with excellent thermal sensitivity (NETD).
  • Intuitive, three-button menu is easy to use—simply navigate with the push of a thumb.
  • Reflected background temperature (reflected temperature compensation)
  • No need to carry pen and paper—record findings by speaking into the camera. Voice annotations can be recorded with every image you take. Voice comments are saved along with individual images for future reference.
  • Everything needed to get started is included.
    Training DVD is now included free. See how easy it is to set up your thermal imager, create professional reports with SmartView software and learn thermograph theory with step-by-step video instructions.
  • Adjustable hand strap for left-or right-handed use.

Specifications

Temperature

Temperature measurement range (not calibrated below -10 °C)

-20 °C to +350 °C (-4 °F to + 662 °F) (two ranges)

Temperature measurement accuracy

± 2 °C or 2 % (whichever is greater)

On-screen emissivity correction

Yes

Imaging performance

Field of view

23° x 17°

Spatial resolution (IFOV)

2.5 mRad

Minimum focus distance

Thermal lens: 15 cm (6 in)

Visible (visual) light lens: 46 cm (18 in)

Focus

Manual

Image frequency

9 Hz refresh rate

Detector type

160 X 120 focal plane array, uncooled microbolometer

Infrared lens type

20 mm F = 0.8 lens

Thermal sensitivity (NETD)

≤ 0.09 °C at 30 °C target temp. (90 mK)

Infrared spectral band

7.5 μm to 14 μm

Visual camera

640 x 480 resolution

Image presentation

Palettes

Ironbow, blue-red, high contrast, amber, hot metal, grey

Level and span

Smooth auto-scaling and manual scaling of level and span

Minimum span (in manual mode)

2.5 °C (4.5 °F)

Minimum span (in auto mode)
Fast Auto/Manual Range Toggle Fast Auto Rescale

5 °C (9 °F)

IR-Fusion® information

Full infrared with MAX, MID, or MIN automatic blending; and picture-in-picture with MAX, MID, or MIN automatic blending (Visual and IR blending)

Picture-In-Picture (PIP)

Three levels of on-screen IR blending displayed in center 320 x 240 pixels

Full screen (PIP off)

Three levels of on-screen IR blending displayed in center 640 x 480 LCD

Image capture and data storage

Voice annotation

60 seconds maximum recording time per image; reviewable playback on imager

Storage medium

SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations or 3000 basic (.bmp) IR images)

File formats

Non-radiometric (.bmp) or fully-radiometric (.is2) No analysis software required for non-radiometric (.bmp) files

Export file formats w/SmartView® software

JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, and EMF

General specifications

Operating temperature

-10 °C to +50 °C (14 °F to 122 °F)

Storage temperature

-20 °C to +50 °C (-4 °F to 122 °F) without batteries

Relative humidity

10 % to 90 % non-condensing

Display

9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD with backlight (selectable bright or auto)

Controls and adjustments

User selectable temperature scale (°C/°F)

Language selection

Time/Date set

Software

SmartView® full analysis and reporting software included

Batteries

Internal rechargeable battery pack (included)

Battery life

Three to four hours continuous use (assumes 50 % brightness of LCD)

Battery charge time

Two hours for full charge

AC operation/charging

AC adapter/charger (110 Vac to 220 Vac, 50 Hz to 60 Hz). Charges battery while imager is operating. Universal ac mains adapters included.

Power saving

Sleep mode activated after 5 minutes of inactivity, automatic power off after 20 minutes of inactivity

Safety standards

CE Directive:IEC/EN 61010-1 2nd Edition Pollution Degree 2

Electromagnetic compatibility

EN61326-1

C Tick

IEC/EN 61326

US FCC

CFR 47, Part 15 Class A

Vibration

2 G, IEC 68-2-29

Shock

25 G, IEC 68-2-29 {2 m (6.5 ft) drop, 5 sides}

Drop

0.27 m x 0.13 m x 0.15 m (10.5 in x 5 in x 6 in)

Dimensions (H x W x L)

1.2 kg (2.65 lb)

Weight (battery included)

2 G, IEC 68-2-29

Enclosure rating

IP54 (protected against dust, limited ingress; protection against water spray from all directions)

Warranty

Two-years (standard)

Recommended calibration cycle

Two-years (assumes normal operation and normal aging)

Supported Languages

Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E