Temperature
|
Temperature measurement range (not calibrated below -10 °C)
|
-20 °C to +250 °C (-4 °F to + 482 °F)
|
Temperature measurement accuracy
|
± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
|
Imaging performance
|
Field of view
|
23° x 17°
|
Spatial resolution (IFOV)
|
2.5 mRad
|
Minimum focus distance
|
Thermal lens: 15 cm (6 in)
Visible (visual) light lens: 46 cm (18 in)
|
Focus
|
Manual
|
Image frequency
|
9 Hz refresh rate
|
Detector type
|
160 X 120 focal plane array, uncooled microbolometer
|
Infrared lens type
|
20 mm F = 0.8 lens
|
Thermal sensitivity (NETD)
|
≤ 0.13 °C at 30 °C target temp. (130 mK)
|
Infrared spectral band
|
7.5 μm to 14 μm
|
Visual camera
|
640 x 480 resolution
|
Image presentation
|
Palettes
|
Ironbow, blue-red, high contrast, grey
|
Level and span
|
Smooth auto-scaling and manual scaling of level and span
|
Minimum span (in manual mode)
|
5 °C (9 °F)
|
Minimum span (in auto mode) Fast Auto/Manual Range Toggle Fast Auto Rescale
|
10 °C (18 °F)
|
IR-Fusion® information
|
Full infrared or picture-in-picture
|
Picture-In-Picture (PIP)
|
100 % IR displayed in center 320 x 240 pixels
|
Full screen (PIP off)
|
100 % IR displayed in center 640 x 480 LCD
|
Palettes
|
Ironbow, blue-red, high contrast, grey
|
Image capture and data storage
|
Storage medium
|
SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each or 3000 basic (.bmp) IR images)
|
File formats
|
Non-radiometric (.bmp) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.bmp) files
|
Export file formats w/SmartView™ software
|
JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, and EMF
|
General specifications
|
Operating temperature
|
-10 °C to +50 °C (14 °F to 122 °F)
|
Storage temperature
|
-20 °C to +50 °C (-4 °F to 122 °F) without batteries
|
Relative humidity
|
10 % to 95 % non-condensing
|
Display
|
9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD with backlight (selectable bright or auto)
|
Controls and adjustments
|
User selectable temperature scale (°C/°F)
Language selection
Time/Date set
|
Software
|
SmartView® full analysis and reporting software included
|
Batteries
|
Internal rechargeable battery pack (included)
|
Battery life
|
Three to four hours continuous use (assumes 50 % brightness of LCD)
|
Battery charge time
|
Two hours for full charge
|
AC operation/charging
|
AC adapter/charger (110 Vac to 220 Vac, 50 Hz to 60 Hz). Charges battery while imager is operating. Universal ac mains adapters included.
|
Power saving
|
Sleep mode activated after five minutes of inactivity, automatic power off after 20 minutes of inactivity
|
Safety standards
|
CE Directive: IEC/EN 61010-1 2nd Edition Pollution Degree 2
|
Electromagnetic compatibility
|
EMC directive: EN61326-1 C-Tick: IEC/EN 61326 US FCC: CFR 47, Part 15 Class A
|
Vibration
|
2 G, IEC 68-2-29
|
Shock
|
25 G, IEC 68-2-29 {2 m (6.5 ft) drop, 5 sides}
|
Dimensions (HxWxL)
|
0.27 m x 0.13 m x 0.15 m (10.5 in x 5 in x 6 in)
|
Weight
|
1.2 kg (2.65 lb)
|
IP rating
|
IP54
|
Warranty
|
Two-years
|
Calibration cycle
|
Two-years (assumes normal operation and normal aging)
|
Supported languages
|
Czech, English, Finnish, French. German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish
|