Description

Detect electrical overloading, energy waste, overheated equipment, moisture intrusion, and other hidden problems instantly with the speed and feature-rich performance of E-Series thermal imaging.

Features

  • High Resolution IR Images - 19,200 pixels (160 x 120) Infrared resolution
  • Automatic Hot/Cold detection
  • Isotherm - Detect High/Low temperature interval
  • Bright LED Light - Allows the visual camera and fusion to be used in poorly lit environments
  • Wide Temperature Range - From -20˚ to +250˚C targeting electrical and industrial applications
  • ± 2% Accuracy - reliable temperature measurement
  • Thumbnail Image Gallery - Allows quick search of stored images
  • Li-Ion Rechargeable Battery - lasts >4hrs continuous use; replaceable
  • Copy to USB - Easy upload of images from camera to USB memory stick
  • Laser LocatIR™ Pointer - Pinpoints a reference spot with a laser
  • Laser Marker - Marks the point on the IR displayed image as to where the Laser pointer is targeting
  • IR Window Correction - Software settings allow you to account for transmission loss through IR windows
  • Area (Min/Max) Mode - Shows the Minimum or the Maximum Temperature reading within the selected area
  • Auto Hot/Cold Spot Marker - Marks the area that automatically finds the hottest or coldest spot within the box

Specifications

Imaging and optical data

Field of view (FOV) / Minimum focus distance

25° × 19° / 0.4 m (1.31 ft.)

Spatial resolution (IFOV)

2.72 mrad

Thermal sensitivity/NETD

< 0.1°C @ +30°C (+86°F) / 100 mK

Image frequency

60 Hz

Focus

Manual

Focal Plane Array (FPA) / Spectral range

Uncooled micro bolometer / 7.5–13 μm

IR resolution

160 × 120 pixels

Image presentation

Display

Touch screen, 3.5 in. LCD, 320 × 240 pixels

Image modes

IR image, thumbnail gallery

Measurement

Object temperature range

–20°C to +120°C , 0°C to +250°C

Accuracy

±2°C (±3.6°F) or ±2% of reading

Measurement analysis

Spotmeter

1

Area

Box with max./min./average

Automatic hot/cold detection

Auto hot or cold spotmeter markers within area

Isotherm

Detect high/low temperature/interval

Reference temperature

Manually set or captured from any measurement function

Emissivity correction

Variable from 0.01 to 1.0 or selected from materials list

External optics/windows correction

Automatic, based on inputs of optics/window transmission and temperature

Measurement corrections

Reflected temperature, optics transmission and atmospheric transmission

Set-up

Color palettes

Arctic, Gray, Iron, Lava, Rainbow and Rainbow HC

Set-up commands

Local adaptation of units, language, date and time formats

Languages

21

Storage of images

Image storage

Standard JPEG, including measurement data, on memory card

Image storage mode

IR images

Data communication interfaces

Interfaces

USB-Mini, USB-A, Composite video

USB

• USB-A: Connect external USB device

• USB Mini-B: Data transfer to and from PC

Video Out

Composite

Power system

Battery

Li Ion, 4 hours operating time

Charging system

In camera (AC adapter or 12 V from a vehicle) or 2-bay charger

Power management

Automatic shutdown and sleep mode (user selectable)

Environmental data

Operating temperature range

–15°C to +50°C (+5°F to +122°F)

Storage temperature range

–40°C to +70°C (–40°F to +158°F)

Humidity (operating and storage)

IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F) / 2 cycles

Encapsulation

IP 54 (IEC 60529)

Bump

25 g (IEC 60068-2-29)

Vibration

2 g (IEC 60068-2-6)

Physical data

Camera weight, incl. battery

0.825 kg (1.82 lb.)

Camera size

246 × 97 × 184 mm (9.7 × 3.8 × 7.2 in.)

Tripod mounting UNC

¼”-20 (adapter needed)

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E