»  Categories   »      GTEM / TEM Cell   »    GTEM/TEM Cell   »    EMC / EMI  
   »  Brands   »  ETS-Lindgren   »  ETS-Lindgren 5411 GTEM Test Cell

image enlarge

ETS-Lindgren 5411 GTEM Test Cell

Description

ETS-Lindgren's GTEM! ™ Test Cell enables users to perform radiated emissions and radiated immunity tests in less time than at either an OATS or in a chamber. Tests can be performed quickly and accurately throughout the product life cycle.

Beginning with design qualification testing and moving through to pre-compliance testing, full compliance testing and production sampling, ETS-Lindgren GTEM!™ Test Cell is a time saving device for your test lab. A typical radiated emissions test (10,000 point scan) can be completed in 15 minutes or less, while a typical radiated immunity test can usually be completed in half the normal time.

The GTEM! ™ Test Cell is based on experience, not experimentation. Originally developed in the EMC Baden (Switzerland) labs of ABB, the cell has been accepted in the EMC community for more than 10 years, and is field proven daily at more than 400 installations worldwide.

Measurements made with a GTEM!™ Test Cell are accepted for final compliance demonstration by the FCC for Part 15 & 18 radiated emissions testing, and comply with IEC 61000-4-3 Annex D for immunity testing. The GTEM!™'s unique tapered shape, offset septum, resistive termination network and absorber- lined back wall remove performance limitations of TEM cells and boxy enclosures. Electromagnetic wave and RF current termination are smooth and controlled. Field uniformity is +/- 3 dB up to 1 GHz, and +/-4 dB above 1 GHz.

Features

  • For all Phases of EMC Testing - Design Qualification - Pre-Compliance - Full Compliance IEC 61000-4-3 ANSI C63.4
  • Post Production

Specifications

Electrical Specifications

Feed Connector Type

cw 7/16 DIN to N Adapter 

Field Uniformity

f 1 GHz, 0 -6dB 

Frequency

9 kHz - 5 GHz (RE) 1 
DC - 20 GHz (RI) 2 

Input Impedance

50 Ω 

Maximum CW Input

1 kW 

Shielding Effectiveness

10 kHz - 1 GHz 
From Internal E-Fields 80 dB min 

VSWR Maximum

All Other Freq 1.50:1 
Characteristic Freq 1.75:1 

VSWR Typical

All Other Freq 1.30:1 
Characteristic Freq3 1.75:1 

Physical Specifications

Approx Cell Weight

900.0 kg   ( 1,984.14 lb ) 

Distributed Load Rating

750 kg   ( 1,653.45 lb ) 

Door Dimension Primary (H)

685.0 mm   (26.97 inches) 

Door Dimension Primary (W)

925.0 mm   (36.42 inches) 

Highest Accuracy Transverse Test Surface in Center of Cell (H)4

366.0 mm   (14.41 inches) 

Highest Accuracy Transverse Test Surface in Center of Cell (W)4

550.0 mm   (21.65 inches) 

Maximum Recommended Transverse Test Surface in Center of Cell (H)5

733.0 mm   (28.86 inches) 

Maximum Recommended Transverse Test Surface in Center of Cell (W)5

825.0 mm   (32.48 inches) 

Maximum Septum Height3

1100.0 mm   (43.31 inches) 

Outer Cell w/Base Dimension(H)1

2.3 m   (7.55 ft) 

Outer Cell w/Base Dimension(L)

5.4 m   (17.72 ft) 

Outer Cell w/Base Dimension(W)

2.8 m   (9.19 ft) 

Electrical Specifications Notes:
1Measurement Range - where correlation to OATS is established: 
3 Measurement - 3 input GTEM-OATS Correlation Algorithm, 30 MHz - 5 GHz
9 Measurement - 9 input GTEM -OATS Correlation Algorithm, 9 kHz - 5 GHz

2Low input VSWR to f£ 20 GHz available

3Characteristic frequency: The frequency at which cross-over between the two terminations (the resistor load boards and the RF absorber) occurs.

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E