»  Categories   »      Combo Wave Generator   »    Generator   »    Surge Generator  

image enlarge

EM TEST VCS 500N8 Combination Wave Simulator 8kV

Description

Surge pulses occur due to direct or indirect lightning strokes to an external (outdoor) circuit. This leads to currents or electromagnetic fields causing high voltage or current transients. Another source for surge pulses is switching transients originating from switching disturbances and systems faults.

Due to the characteristic of the phenomenon nearly every electrical and electronically a device may suffer from such lightning events which justifies the necessity of surge tests being widely performed. Surge voltage can reach several thousands of volts and surge current is seen to reach several thousands of amps.

Although generating voltages as high as 8kV the VCS 500N8 offers a integrated coupling/decoupling network either single phase or three-phase with a nominal current of 16A per phase. In case higher current is required its capability can be extended by an external CDN to achieve nominal currents of 100A and more per phase.

By selecting the desired coupling the source impedance and the coupling capacitor is set automatically whatever CDN is connected.

Fail inputs are offered as standard for DUT monitoring purposes. Peak values of voltage and current are shown in the display and these values are transferred to the software for reporting.
To comply with safety regulations the VCS 500N8 is equipped with a contact to control warning lamps and with a safety interlock.

Pre-programmed Standard Test routines allow highest user convenience. Still the VCS 500N8 offers the Quick Start test routine where parameters can be changed on-line during the test to evaluate the susceptibility level of an individual DUT.

Features

  • Surge voltage up to 8kV
  • Surge current up to 4kA
  • Voltage/current monitors
  • Built-in CDN 1-phase or 3-phase up to 3 x 690V and 32A
  • Interlock
  • Warning lamp control
  • Manual operation
  • USB and GPIB interface

Specifications

COMBINATION WAVE 1.2/50US - 8/20US

Voltage (o.c.)

250V - 8,000V ± 10%

Front time

1.2μs ± 30%

Time to half value

50μs ± 20%

Current (s.c.)

Max. 4,000A ± 10%

Front time

8μs ± 20%

Time to half value

20μs ± 20%

Polarity

Positive/negative/alternating

Event counter

1 - 30,000 or endless

INTERFACE

Serial interface

USB

Parallel serial interface

IEEE 488, addresses 1 - 30

SAFETY

Safety circuit

Control input (24Vdc)

Warning lamp

Floating output contact

DIMENSIONS

 

Dimension - Weight

19"/6HU, approx. 25kg

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E