»  Categories   »      Combo Wave Generator   »    Generator   »    Surge Generator  

image enlarge

EM TEST VCS 500N12 Combination Wave Simulator 12kV

Description

Surge pulses occur due to direct or indirect lightning strokes to an external (outdoor) circuit. This leads to currents or electromagnetic fields causing high voltage or current transients. Another source for surge pulses is switching transients originating from switching disturbances and systems faults.

Due to the characteristic of the phenomenon nearly every electrical and electronically a device may suffer from such lightning events which justifies the necessity of surge tests being widely performed. Surge voltage can reach several thousands of volts and surge current is seen to reach several thousands of amps.

The VCS 500N12 combination wave simulator generates surge voltages up to 12kV and surge currents up to 6kA as it is required for component testing (e.g. overvoltage protection for telecommunication devices). To apply the surge pulses to power supply lines an external coupling/decoupling network either single phase or three-phase can be connected. The coupling modes and the source impedance are set automatically controlled by the VCS 500N12.
Fail inputs are offered as standard for DUT monitoring purposes. Peak values of voltage and current are shown in the display and these values are transferred to the software for reporting.

To comply with safety regulations the VCS 500N12 is equipped with a contact to control warning lamps and with a safety interlock.

Pre-programmed Standard Test routines allow highest user convenience. Still the VCS 500N12 offers the Quick Start test routine where parameters can be changed on-line during the test to evaluate the susceptibility level of an individual DUT.

Features

  • Surge pulses up to 12kV/6kA
  • Single phase or three-phase coupler up to 100A (external option)
  • Fail inputs
  • Warning lamp control
  • Emergency interlock
  • Standard Test routines
  • USB and GPIB interface

Specifications

COMBINATION WAVE 1.2/50US - 8/20US

Voltage (o.c.)

500V - 12,000V ±10%

Rise time

1.2us ± 30%

Pulse time to half value

50us ± 20%

Current (s.c.)

max. 6,000A ±10%

Rise time

8us ± 20%

Pulse time to half value

20us ± 20%

Polarity

Positive/negative/alternating

Event counter

1 - 30,000 or endless

INTERFACE

Serial interface

USB

Parallel interface

IEEE 488, addresses 1 - 30

CN interface

To control external coupling matrix

DIMENSIONS

Dimensions

19"/6HU

Weight

approx. 35kg

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E