»  Categories   »      Generator   »    Dips & Interrupts   »    EMC / EMI   »    Power Fail Generator   »    Mains Dips & Drops  

image enlarge

EM TEST PFS 503N Series Power Fail Simulators

Description

Electronic and electrical equipment may be affected by voltage dips, short interruptions and voltage variations of the power supply. Dips and interruptions are caused by faults in the public supply network, in installations or by sudden large change of load. Testing to such phenomena is required to proof that electronic and electrical equipment do not fall into unsafe operation conditions.

Unlike any other Power Fail simulator the EM TEST PFS 503N Series represents a real three-phase Power Fail simulator. Not only phase-by-phase testing is possible but any combination of phases and all three phases can be simultaneously tested. Therefore the PFS503N Series is equipped with six individually controlled semiconductor switches. Each switch is electronically short-circuited protected. Additionally the PFS 503N Series is available for nominal currents of up to 100A which is another outstanding and unreached feature for Power Fail testing.

The PFS 503N Series offers BNC outputs for individual current monitoring for each phase by means of an oscilloscope. The inrush current can be measured using these BNC outputs. An analog DC signal of 0 to 10V is supplied to drive an external motorized three-phase variac.

Features

  • Standalone test generator for dips, short interruptions and voltage variation
  • Full-compliant three-phase system as per IEC 61000-4-11, Ed.2:2004 and IEC 61000-4-34 for testing delta and star supply systems
  • 6 electronic switches, short-circuit protected
  • Rated voltage up to 3x690V AC, 600V DC
  • Nominal current up to 100A per phase
  • DC signal to control external variac
  • Front panel operation
  • Standard Test routines
  • USB and GPIB interfaces

Specifications

PFS 503N SERIES MODEL CONFIGURATION

PFS 503N32

3x480V AC, max. 32A per phase

277V AC (L-N), 360V DC

PFS 503N63

3x480V AC, max. 63A per phase

277V AC (L-N), 360V DC

PFS 503N100

3x480V AC, max. 100A per phase

277V AC (L-N), 360V DC

PFS 503N32.1

3x690V AC, max. 32A per phase

400V AC (L-N), 600V DC

PFS 503N63.1

3x690V AC, max. 63A per phase

400V AC (L-N), 600V DC

PFS 503N100.1

3x690V AC, max. 100A per phase

400V AC (L-N), 600V DC

POWER SWITCHES

 

Three-phase application

Voltage

(L-L) 3x480V AC resp. 3x690V AC

Frequency

50Hz/60Hz

Single phase application

Voltage

(L-N) 277V AC resp. 400V AC

360V DC resp. 600V DC

Frequency

50Hz/60Hz and DC

Current AC/DC

Max. 32A (PFS 503N32/N32.1)

Max. 63A (PFS 503N63/N63.1)

Max. 100A (PFS 503N100/N100.1)

Peak current

PFS 503N32/N32.1:

Better than 500A

PFS 503N63/N63.1 and

PFS 503N100/N100.1:

Better than 1,000A as per IEC 61000-4-34

Fall/rise time

Between 1us and 5us for abrupt changes, generator loaded with resistive load

Switches are electronically protected against short-circuit

INTERFACES

Serial

USB

Parallel

IEEE 488, addresses 1 to 30

Analog output

0 to 10 V DC to control an external motor variac

GENERAL DATA

Dimensions

19"/6 HU

Weight

app. 28kg;

PFS 503N100/N100.1 app. 35kg

Supply voltage

115V/230V; +10/-15%

Fuses

2 x T 1A (230V) or 2 x T 2A (115V)

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E