»  Categories   »      Power Fail Generator   »    Generator   »    Dips & Interrupts   »    Automotive   »    EMC / EMI   »    Automotive EMC   »    Mains Dips & Drops  

image enlarge

EM TEST PFS 200N Automotive Fail Simulator

Description

The PFS 200N Automotive Power Fail simulator is used to comply with standard requirements, mainly from vehicle manufacturers, to perform fast voltage dips ad drops (micro-interruptions). Some standards specify very fast rise and fall times below 1 microsecond an electronic switch.

The PFS 200N is a standalone tester providing an electronic switch to perform voltage dips and drops (micro-interruptions) with fast rise and fall times of 1 microsecond. For voltage dips two DC voltage supplies are required while for voltage drops (micro-interruptions) only one DC voltage supply is needed. The PFS 200N has the ability to control one external DC voltage source by means of an analog DC signal. The PFS 200N can also be easily integrated into a complete test set-up.

Operation is possible both manually and by software via USB or GPIB. Fail inputs allow controlling an ongoing test sequence based on the status of the DUT. Pre-programmed Standard Test routines allow highest user convenience. Still the PFS 200N offers the Quick Start test routine where parameters can be changed on-line during a test to evaluate the susceptibility level of an individual DUT.

Features

  • Standalone test generator for voltage dips and interruptions
  • Rise/fall time <1us
  • Electronic short-circuit protection
  • Rated voltage 60V DC
  • Front panel operation
  • Standard Test routines
  • USB and GPIB interfaces

Specifications

EM TEST PFS 200N Specifications

PFS 200N MODELS

PFS 200N30

Power Fail Simulator 60V/30A

PFS 200N50

Power Fail Simulator 60V/50A

PFS 200N100

Power Fail Simulator 60V/100A

PFS 200N150

Power Fail Simulator 60V/150A

PFS 200N200

Power Fail Simulator 60V/200A

TECNICAL DATA PFS 200N30

DUT voltage

Max. 60V for channels PF1/PF2

DUT current

Max. 30A for channels PF1/PF2

Switching time

1us (rise/fall time)

Peak current

70A for 500ms

Safety

Short circuit protection

TECNICAL DATA PFS 200N50

DUT voltage

Max. 60V for channels PF1/PF2

DUT current

Max. 50A for channels PF1/PF2

Switching time

1us (rise/fall time)

Peak current

100A for 500ms

Safety

Short circuit protection

TECNICAL DATA PFS 200N100

DUT voltage

Max. 60V for channels PF1/PF2

DUT current

Max. 100A for channels PF1/PF2

Switching time

1us (rise/fall time)

Peak current

150A for 500ms

Safety

Short circuit protection

TECNICAL DATA PFS 200N150

DUT voltage

Max. 60V for channels PF1/PF2

DUT current

Max. 150A for channels PF1/PF2

Switching time

1us (rise/fall time)

Peak current

200A for 500ms

Safety

Short circuit protection

TECNICAL DATA PFS 200N200

DUT voltage

Max. 60V for channels PF1/PF2

DUT current

Max. 200A for channels PF1/PF2

Switching time

1us (rise/fall time)

Peak current

Greater than 200A

Safety

Short circuit protection

GENERAL DATA

Dimensions, Weight

19"/3HU approx. 15kg;

19"/6HU, approx. 18kg for PFS 200N150 and PFS200N200

Supply voltage

115V/230V +10/-15%

Fuses

2 x T 1AT

INTERFACE

Interface

USB

Parallel interface

IEEE 488, addresses 1 to 30

Analog interface

OVdc to 10Vdc to control an external dc source (e.g. RDS 200N)

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E