Com-Power PAM-118 Preamplifier 500 MHz – 18 GHz

Description

The model PAM-118 is a broadband, high gain, bench top microwave preamplifier. The PAM-118 has a frequen¬cy range of 500 MHz to 18 GHz. This preamplifier is primarily intended for EMC applications. However, it can be used for other applications that require signal amplification. The PAM-118 reduces floor noise and increases system sensitivity to low level signals during Electromagnetic Interference (EMC) testing.

The simple front panel consists of two 50 Ohm matched SMA connectors for input and output. The preamplifier was designed to have minimal gain variation for the entire frequency range. The consistent gain reduces EMC measurement errors. It also has low VSWR and noise figure.

Each preamplifier is individually calibrated using equipment traceable to National Institute of Standards and Technology. The data and certificate of calibration is shipped with the unit. The PAM-118 is powered by 18 VDC, 1 Amp wall plug adapter.

Features

  • Ultra Wideband - 500 MHz - 18 GHz
  • High Gain - 24 dB minimum
  • Flat Response - ± 1.25 dB.
  • Low Noise Figure - 3 dB max.
  • Power @1 dB Gain Compression - +17 dBm

Com-Power PAM-118 Application

The PAM-118 preamplifier increases system sensitivity to low level signals from equipment under test during EMC testing. It also provides input isolation to your spectrum analyzer or receiver.

During EMC measurements the antennas are usually placed at a distance of 1 -10 meters from the equip­ment under test. Most antennas operating above 1 GHz typically have high antenna factors. In addition, long interconnecting cables operating in the microwave fre­quencies usually have high cable losses. These factors make it difficult to see the radiation from the equip­ment under test above the floor noise of the spectrum analyzer. The preamplifier improves system sensitivity by amplifying the signals picked by the antenna before it reaches the spectrum analyzer.

The system sensitivity can be further improved by connecting the PAM-118 preamplifier right at the antenna output. Placing the preamplifier close to the receiving antenna will reduce the effects of high cable loss associated with long cables.

Specifications

Frequency

500 MHz - 18000 MHz

Gain

24 dB

Flatness

± 1.25 dB

Noise Figure

3 dB max.

VSWR (Input / Output)

2.5: 1 / 2.5: 1

P1dB Comp

+17 dBm, minimum

DC Input

0 VDC, max.

Input power handling

+10 dBm, CW

Reverse Isolation

40 dB, typical

Power

18 VDC, 1 Amp

Impedance

50 Ohm

Connector type

SMA

Operating Temperature

+ 25 C

Size

7.7" x 6.5" x 3.2" (18.4 cm x 15.6 cm x 7.7 cm)

Weight

2.5 lbs. (5.5 kg)

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E