»  Categories   »      PIM Test Solution   »    PIM Analyzer   »    Analyzer  

image enlarge

AWT Global PIM S1L Laboratory PIM Analyzers

Description

Passive Intermodulation (PIM) is an unwanted mixing effect caused by non-linearity of passive components in the RF path of telecommunication systems. PIM diverts signal energy to other frequencies (spurious signals). This can generate interfering signals that may fall into receiving bands causing serious degradation of system performance.

PIM S1L testers are ideal for component testing in the laboratory and/or during quality control. They provide a wealth of features that deliver accurate and reliable results. They are very easy to operate; it takes just one click to start a predefined test.

Modern telecommunication technologies demand PIM testing of network infrastructures and their components. Low PIM components are particularly important when wireless frequencies are combined. Signal degradation caused by PIM causes loss of capacity, which translates directly into dissatisfied customers as well as reduced revenues for the operators. Low PIM components are key to network optimization.

Features

  • Test Modes: Diagnostic, Analyzer with Graphs, Sweep Mode (option), Distance to PIM (option), Distance to Fault (option)
  • Very high PIM sensitivity: -172 dBc @ 2x 43 dBm carriers
  • Output power variable from 15dBm to 44dBm. Perfect for IEC 62037 measurements, as well as for low power in-building DAS components
  • Measures intermodulation products IM3, IM5 IM7, IM9, IM11 and IM13
  • PIM over Time Graph and Sweep Mode
  • Maxhold feature
  • Data recording: CSV, PDF, Screenshot (BMP)

Specifications

Model Number

Technologies / Type

Tx Frequency (MHz)

Rx Frequency (MHz)

PS1L-700U

LTE700 / 700 MHz Upper Band

730 ~ 759

776 ~ 788

PS1L-700L

LTE700 / 700 MHz Lower band

728 ~ 759

698 ~ 716

PS1L-800

LTE800

791 ~ 821

832 ~ 862

PS1L-850

CDMA850 / 850 MHz

869 ~ 896

824 ~ 851

PS1L-900

GSM900 / 900 MHz

935 ~ 960

890 ~ 915

PS1L-900E

EGSM900

925 ~ 960

880 ~ 915

PS1L-1500

LTE-1500 Japan / 1500 MHz

1488 ~ 1520

1456 ~ 1480

PS1L-1800

GSM 1800 / DCS 1800 / 1800 MHz

1805 ~ 1880

1710 ~ 1785

PS1L-1900

PCS 1900 / 1900 MHz

1930 ~ 1990

1850 ~ 1910

PS1L-1921PA

PCS 1900/ 1900 MHz
AWS Band

1930 ~ 1935
2110 ~ 2155

1710 ~ 1755

PS1L-2100AWS

AWS

2110 ~ 2155

1710 ~ 1755

PS1L-2000TD

TD-SCDMA(2000)

2010 ~ 2025

1900 ~ 1920

PS1L-2100UMTS

UMTS/W-CDMA / 2100 MHz

2110 ~ 2170

1920 ~ 1980

PS1L-2160JP

W-CDMA-JP

2150 ~ 2170

2110 ~ 2140

PS1L-2600LTE

IMT-E(2600) / LTE 2600 / 2600 MHz

2620 ~ 2690

2500 ~ 2570

Accessories

POPT001

VSWR / DTP (Distance to PIM) Option

POPT002

Accessory Kit: (2) low PIM cables 3m / 10ft, (1) low PIM cable 1m / 3ft, low PIM load 100W, adapters, torque wrench with hard carry case

POPT004

PIM Source: Generator with preset PIM value. Quick indication of system functionality. Ideal for test and training.

Transmitter

Carrier Power

+15 to +44 dBm (46 dBm optional)

Power Accuracy

+/- 0.35 dB

Frequency Accuracy

200 ppm

Reverse Pwr. Protection

+43 dBm for 5 sec

Receiver

Reverse IM @ 2x43dBm

-129 dBm / -172 dBc typ.

Noise Floor

-138 dBm (300 Hz Bandwidth)
-132 dBm (1200 Hz Bandwidth)

DynamicRange(typical)

> 96 dB (ref: -90 dBm)

Reverse Power Protection

+43 dBm for 5 sec

Operational Input Power

-45 dBm RMS

Max Input Power

-10 dBm

Measurement Accuracy

+/- 2 dB @ 2 x 43 dBm

Distance to PIM / Distance to VSWR (Option)

DTP Accuracy

0.5 m typ.

DTF Accuracy (VSWR)

0.5 m

Cable Types

Built-in list of cables
Editing and adding new cable types

Dimensions / Weight / Environment / Electrical

Dimensions

521 x 396 x 236 (mm)
20.5 x 15.6 x 9.3 (inch)

Weight

25.3 kg (55.7 lb)

Temperature

0 °C to +45 °C

Humidity

85%, RH (non condensing)

Protection

IP20

AC Power

100 to 240V 50/60 Hz

Power Consumption

640 Watts (VA)

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E