»  Categories   »      PIM Test Solution   »    PIM Analyzer   »    Analyzer  

image enlarge

AWT Global PIM Analyzers – Single Band

Description

AWT’s PIM Analyzers are ideal for production and laboratory. These instruments are very accurate, yet highly reliable and built for true continuous 24/7 operation. The complete system consists only of one unit, making set-up easy and operation convenient.

With the introduction of new wireless technologies like LTE, and LTE-A, network operators demand RF components that offer excellent PIM characteristics. AWT’s PIM Analyzers are well suited for this task. With -172dBc sensitivity, our analyzers detect all PIM issues of tested RF components. Engineers appreciate the high accuracy over 100% of the IM measurements.

Features

  • Precision PIM Analyzer for production and laboratory
  • True 24/7 operation
  • 3 Measurement modes: PIM Analyzer, PIM over Time, PIM over Frequency (Frequency Sweep)
  • Forward and reverse PIM measurements ( 2-port)
  • One unit of equipment holds the complete PIM Analyzer system

Specifications

Model Number / Type

Tx Frequency (MHz)

Rx Frequency (MHz)

TETRA 400

390 ~ 400

380 ~ 384

E-TETRA400

420 ~ 430

410 ~ 412

AMPS/CDMA

869 ~ 896

824 ~ 851

GSM900

935 ~ 960

890 ~ 915

EGSM900

925 ~ 960

880 ~ 915

LTE-JP1500

1488 ~ 1520

1456 ~ 1480

DCS/GSM1800

1805 ~ 1880

1710 ~ 1785

PCS1900

1930 ~ 1990

1850 ~ 1910

AWS

2010 ~ 2155

1710 ~ 1755

TD-SCDMA(2000)

2010 ~ 2025

1900 ~ 1920

UMTS/W-CDMA

2110 ~ 2170

1920 ~ 1980

W-CDMA-JP

2150 ~ 2170

2110 ~ 2140

IMT-E(2600)

2620 ~ 2690

2500 ~ 2570

WiBro-KR

2110 ~ 2170
2300 ~ 2390

1910 ~ 1990

Accessories

Opt. 2

Accessory Kit: (2) low PIM cables 3m / 10ft, (1) low PIM cable 1m / 3ft, low PIM load 100W, adapters, torque wrench with hard carry case

Opt. 3

Low PIM Load 100W, < 165 dBc @ 2* 43W, DIN 7/16 (f)

Opt. 4

PIM Source: Generator with preset PIM value. Quick indication of system functionality. Ideal for test and training.

Transmitter

Carrier Power

+20 to +44 dBm (46 dBm optional)

Power Accuracy

+/- 0.35 dB

Frequency Accuracy

200 ppm

Reverse Pwr. Protection

+43 dBm for 5 sec

Receiver

Reverse IM @ 2x43dBm
Forward IM @ 2x43dBm

-129 dBm / -172 dBc typ.
-125 dBm / -168 dBc typ.

Noise Floor

-140 dBm (300 Hz BW)

Dynamic Range(typical)

> 96 dB (ref: -70 dBm)

Reverse Power Protection

+43 dBm for 5 sec

Operational Input Power

-40 dBm RMS

Max Input Power

-10 dBm

Measurement Accuracy

+/- 0.2 dB @ 2 x 43 dBm

Warm-up time (for full measurement accuracy)

10 mins

Dimensions / Weight / Environment / Electrical

Dimensions
All units (except E-GSM)
E-GSM units

488 x 653 x 278 (mm)
488 x 719 x 278 (mm)

Weight
All units (except E-GSM)
E-GSM units

35 kg
36 kg

Temperature

-10 °C to +40 °C

Humidity

80%, RH (non condensing)

Protection

IP20 (indoor use)

AC Power

100 to 240V 50/60 Hz

Power Consumption

750 Watts (VA)

Note: All data is subject to change without further notice.

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E