»  Categories   »      PIM Test Solution   »    PIM Analyzer   »    Analyzer  
   »  Brands   »  AWT Global   »  AWT Global Expandable PIM Analyzers

image enlarge

AWT Global Expandable PIM Analyzers

Description

Production testing requires fast and highly reliable PIM analyzers. As the spectrum of manufactured products widens, PIM analysis may have to be performed on additional frequencies. AWT Global’s PIM Analyzer can be equipped with one to four different RF Units.

AWT’s Expandable PIM Analyzers grow with widening manufacturing requirements. The Main Control Unit can handle up to four RF Units with different frequency bands. To minimize expenses, customers can choose to start with only one basic frequency band and install additional RF Units later when needed. There is no need to send units back to the factory for the upgrade; additional RF Units can be installed in the field.

Whether growing with demand, or offering greatest flexibility with four frequency bands, AWT’s Expandable PIM Analyzers are a cost efficient solution for manufacturing and laboratory.

Features

  • Control Unit can control up to 4 different RF Units.
  • 3 Measurement Modes: PIM Analyzer, PIM over Time, PIM over Frequency (Frequency Sweep).
  • RF Units measure forward & reverse PIM (2-port).
  • Measures Intermodulation products IM3, IM5 IM7, IM9, IM11 and IM13

Specifications

Model Number / Type

Tx Frequency (MHz)

Rx Frequency (MHz)

Master Control Unit
(controls up to 4 RF Units)

All

All

RF Units

TETRA 400

390 ~ 400

380 ~ 384

E-TETRA400

420 ~ 430

410 ~ 412

AMPS/CDMA

869 ~ 896

824 ~ 851

EGSM900

925 ~ 960

880 ~ 915

GSM900

935 ~ 960

890 ~ 915

LTE-JP1500

1488 ~ 1520

1456 ~ 1480

DCS/GSM1800

1805 ~ 1880

1710 ~ 1785

PCS1900

1930 ~ 1990

1850 ~ 1910

AWS

2010 ~ 2155

1710 ~ 1755

TD-SCDMA(2000)

2010 ~ 2025

1900 ~ 1920

UMTS/W-CDMA

2110 ~ 2170

1920 ~ 1980

W-CDMA-JP

2150 ~ 2170

2110 ~ 2140

IMT-E(2600)

2620 ~ 2690

2500 ~ 2570

WiBro-KR

2110 ~ 2170
2300 ~ 2390

1910 ~ 1990

Accessories

Opt. 2

Accessory Kit: (2) low PIM cables 3m / 10ft, (1) low PIM cable 1m / 3ft, low PIM load 100W, adapters, torque wrench with hard carry case

Opt. 3

Low PIM Load 100W, < 165 dBc @ 2* 43W, DIN 7/16 (f)

Opt. 4

PIM Source: Generator with preset PIM value. Quick indication of system functionality. Ideal for test and training.

Transmitter

Carrier Power

+20 to +44 dBm (46 dBm optional)

Power Accuracy

+/- 0.35 dB

Frequency Accuracy

200 ppm

Reverse Pwr. Protection

+43 dBm for 5 sec

Receiver

Reverse IM @ 2x43dBmForward IM @ 2x43dBm

-129 dBm / -172 dBc typ.-125 dBm / -168 dBc typ.

Noise Floor

-140 dBm (300 Hz BW)

DynamicRange(typical)

> 96 dB (ref: -70 dBm)

Reverse Power Protection

+43 dBm for 5 sec

Operational Input Power

-40 dBm RMS

Max Input Power

-10 dBm

Measurement Accuracy

+/- 0.2 dB @ 2 x 43 dBm

Dimensions / Weight / Environment / Electrical

Dimensions
Control Unit
RF Units (exc. E-GSM)
RF Units E-GSM

483 x 305 x 500 (mm)
483 x 667 x 143 (mm)
483 x 756 x 143 (mm)

Weight
Control Unit
RF Units

11.7 kg
25 – 28 kg

Temperature

-10 °C to +40 °C

Humidity

80%, RH (non condensing)

Protection

IP20

AC Power

100 to 240V 50/60 Hz

Power Consumption
Control Unit
RF Units

88 Watts (VA)
700 Watts (VA) max

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E