»  Categories   »      Data Analyzer   »    Communications Analyzer   »    Analyzer  

image enlarge

Anritsu MT8802A Radio Communication Analyzer 300 kHz - 3 GHz

Description

The MT8802A was designed to support the test needs of the manufacturing, R&D and maintenance markets. All major radio communication systems in the world, including IS-95, GSM/DCS1800/PCS1900, IS-136A, AMPS/NAMPS, PDC, and PHS, can be evaluated using just one MT8802A Radio Communication Analyzer, covering the 300 kHz to 3 GHz frequency band in one hardware platform, and the dedicated measurement software options. This tester supports Service Options 1, 2 and 9 for IS-95 and J-Std-008 as well as call processing and sensitivity testing using the loopback method for GSM/DCS1800/PCS1900 and IS-136A. The call processing function, transmission/reception measurement functions, analog measurement function, and thermocouple power meter are provided as standard features. And when the spectrum analyzer function is added as an option, the MT8802A becomes a general-purpose spectrum analyzer that covers the frequency range of 10MHz to 3GHz.

FM radio transmission/reception tests are simplified by using the analog measurement function, and the optional spectrum analyzer function covering 10 MHz to 3 GHz is very useful for maintaining and measuring spurious near carrier on production lines. GPIB and RS-232C interfaces are standard, so MT8802A can be incorporated easily into automated production lines or on-site automated testing systems.

The time required for testing equipment on production lines is greatly reduced using the high-speed adjacent channel power and occupied bandwidth measurement functions based on Anritsu's proprietary measurement algorithm and DSP (Digital Signal Processing).

Furthermore, major transmission test items such as transmission frequency, modulation accuracy (phase error), transmission power, rise/fall characteristics of burst wave, adjacent channel power, etc. can be measured.

Features

  • One-Box tester for CDMA measurement
  • Call processing functions
  • Cellular and PCS bands
  • Access probe output power measurement
  • Waveform quality measurement
  • Openloop power control time response measurement
  • Wide-band power meter
  • Frame error rate measurement
  • Analog measurement functions
  • Spectrum analyzer function

Specifications

AF Oscillator

Frequency

Range: 20 Hz to 20 kHz; Setting resolution: 0.1 Hz; Accuracy: Synchronized with reference oscillator

Output level

Range: 0.1 mVrms to 3 Vrms (EMF) *MAIN output: 600 ½

0.1 mVrms to 0.3 Vrms (EMF) *MAIN output: 50 ½

Setting resolution: 1 μV (<4 mV), 10 μV (<40 mV), 100 μV (<0.4 V), 1 mV (²3 V)

AF oscillator Accuracy (bandwidth: <30 kHz)

Unbalanced output: ±0.5 dB (1 kHz, ³1 mV), ±1 dB (20 Hz to 20 kHz, ³1 mV)

Floating output: ±2 dB (1 kHz, ³1 mV)

Output impedance

MAIN: 600 ½/50 ½ selectable, unbalanced, BNC

Microphone: 600 ½, floating, DUT I/F

Distortion: ²–50 dBc (1 kHz, 1 V), ²–45 dBc (20 Hz to 20 kHz, 1 V) *Bandwidth: <30 kHz

Noise generator: White noise passed through a weighting filter (conforming to ITU-T Rec. G.227)

RF Analyzer

Power meter (narrow band)

Frequency range: 10 MHz to 3 GHz

Level range: 0 to +40 dBm (Main), –40 to +20 dBm (AUX)

Accuracy: ±10% (Main, after calibration with internal wide band power meter)

±1 dB (AUX, 18° to 28°C, reference level: ³–12 dBm, after calibration)

Linearity: ±0.3 dB (0 to –30 dB)

Frequency counter

Frequency: 10 MHz to 3 GHz

Input level: –20 to +40 dBm (Main), –40 to +20 dBm (AUX)

Resolution: 1 Hz

Accuracy: ± (reference oscillator accuracy + 10 Hz)

Measurement method: IF frequency counting (bandwidth: ±30 kHz)

FM measurement

Frequency: 10 MHz to 3 GHz

Input level: –20 to +40 dBm (Main), –40 to +20 dBm (AUX)

Filters

HPF: 50 Hz, 300 Hz (3 dB cut-off frequency); LPF: 3 kHz, 15 kHz (3 dB cut-off frequency)

Frequency deviation: 0 to 20 kHz

Demodulation frequency: 30 Hz to 20 kHz

Accuracy: 1% + residual FM (demodulation frequency: 1 kHz)

Frequency characteristics: ±0.5 dB (referenced to demodulation frequency 1 kHz)

Residual FM: 8 Hzrms (demodulation frequency: 0.3 to 3 kHz)

RF analyzer Distortion: 0.3% (demodulation frequency: 1 kHz, demodulation bandwidth: 0.3 to 3 kHz, frequency deviation: 5 kHz)

øM measurement

Frequency range: 10 MHz to 3 GHz

Input level range: –20 to +40 dBm (Main), –40 to +20 dBm (AUX)

Filters

HPF: 50 Hz, 300 Hz (3 dB cut-off frequency)

LPF: 3 kHz, 15 kHz (3 dB cut-off frequency)

Phase deviation: 0 to 10 rad

Demodulation frequency: 300 Hz to 3 kHz

Accuracy: 1% + residual øM (demodulation frequency: 1 kHz)

Frequency characteristics: ±0.5 dB (referenced to demodulation frequency 1 kHz)

Residual øM: 0.01 rad-rms (demodulation frequency: 0.3 to 3 kHz)

Distortion: 0.5% (demodulation frequency: 1 kHz, demodulation bandwidth: 0.3 to 3 kHz, frequency deviation: 5 rad)

FM demodulation output

Frequency deviation: 0 to 40 kHz (4/40 kHz range)

Demodulation frequency: 50 Hz to 10 kHz

Output level: 4 Vpeak (EMF, at full-scale)

Output impedance: 600 ½

Frequency characteristics: ±1 dB (referenced to demodulation frequency 1 kHz)

Distortion: 1% (demodulation frequency: 1 kHz, demodulation bandwidth: 0.3 to 3 kHz, frequency deviation: 4 kHz, 4 kHz range)

Filters

HPF: 300 Hz (3 dB cut-off frequency), LPF: 3 kHz (3 dB cut-off frequency)

De-emphasis: 750 μs

Audio Analyzer

Input impedance: 600 ½/100 k½ selectable, unbalanced, BNC

Bandpass filter

HPF: 400 Hz (for tone rejection), De-emphasis: 750 μs

Weighting filter: ITU-T P.53/C-MESSAGE selectable

Audio analyzer AF level measurement

Frequency: 30 Hz to 20 kHz; Level: 1 mVrms to 30 Vrms; Accuracy: ±0.5 dB

Distortion measurement

Frequency: 100 Hz to 5 kHz; Level: 30 mVrms to 30 Vrms; Accuracy: ±1 dB (frequency: 1 kHz, distortion: 1%)

AF frequency measurement

Frequency: 30 Hz to 20 kHz; Level: 30 mVrms to 30 Vrms; Accuracy: ±0.1 Hz

Other

Display

Color TFT-LCD, Size : 7.8 inches; Number of dots : 640 x 480 dots

Hard copy: Enable data hard copy of the display through a parallel interface (applicable for ESC/P)

GPIB: This equipment is specified as a device, can be controlled from external controller.

Not available controller function (excluding power switch and FD ejection)

Interface function: SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, C0, E2

Parallel interface

Others Conforms to the Centronics, outputs printing data to printer

Data line exclusive for output: 8

Control line: 4 (BUSY, DTSB, ERROR, PE)

Connector: D-sub 25 pins, female

RS-232C: All functions controlled by external controller (excluding power switch and FD ejection)

Baud rate: 1200, 2400, 4800, 9600 bps

Dimensions and mass: 426 (W) x 221.5 (H) x 451 (D) mm, ²27 kg

Power: 100 to 120/200 to 240 Vac (automatic voltage switch system), 47.5 to 63 Hz, ²300 VA

Operating temperature: 0° to +50°C

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E