»  Categories   »      Data Analyzer   »    Communications Analyzer   »    Analyzer  

image enlarge

Anritsu MT8801B Radio Communication Analyzer 300 kHz - 3 GHz

Description

Every major radio communication system in the world, including GSM/DCS1800/PCS1900, IS-136A, PDC and PHS, can be evaluated using just one MT8801B Radio Communication Analyzer, covering the 300 kHz to 3 GHz frequency band in one hardware platform, and the dedicated measurement software options. The call processing test and sensitivity test using loopback method are possible for GSM/DCS1800/PCS1900 and IS-136A.

In addition, connection testing, as well as send testing while communicating, is also possible for PDC and PHS measurement by using the call processing function. And the PDC uplink RCH cans be monitored (RSSI, estimated error rate) too. FM radio transmission/reception tests are simplified by using the optional analog measurement function. And the optional spectrum analyzer function covering10 MHz to 3 GHz is very useful for maintenance as well as for measuring spurious near carrier on production lines. GPIB and RS-232Cinterfaces are standard, so MT8801B can be incorporated easily into automated production lines or on-site automated testing systems. The time required for testing equipment on production lines is greatly reduced using the high-speed adjacent channel power and occupied bandwidth measurement functions based on Anritsu's proprietary measurement algorithm and DSP (Digital Signal Processing). Furthermore, major transmission test items such as transmission frequency, modulation accuracy (phase error), transmission power, rise/fall characteristics of burst wave, adjacent channel power, etc., can be measured and judged pass/fail for limit value of the each item.

Features

  • 1 unit for GSM, IS-136A, PDC and PHS systems
  • All basic transmission and reception measurements performed by 1 unit

System type

Measurement software

Description

IS-136A

MX880113A

Tx and Rx measurements of IS-136A mobile stations including call processing (requires option 01 and 02)

GSM

DCS1800

PCS1900

MX880115A

Tx and Rx measurements of GSM system mobile stations including call processing (requires option 02)

PDC

MX880116A

Tx and Rx measurements of PDC mobile stations including call processing (requires option 02)

MX880131A

Tx and Rx measurements of PDC mobile stations

PHS

MX880117A

Tx and Rx measurements of PHS mobile stations including call processing (requires option 02)

MX880132A

Tx and Rx measurements of PHS mobile stations

Specifications

Frequency range

300 kHz to 3 GHz

Maximum input level

+40 dBm (10 W, MAIN connector), +20 dBm (100 mW, AUX connector)

MAIN I/O connector

Input/output connector Impedance: 50 ½, N-type

VSWR: ²1.2 (²2.2 GHz), ²1.3 (>2.2 GHz)

AUX input/output connector: TCN-type

Reference oscillator

Frequency: 10 MHz

Starting characteristics: ²5 x 10–8/day (after 10 minutes of warm-up, referred to frequency after 24 hours warm-up)

Aging rate: ²2 x 10–8/day, ²1 x 10–7/year (referred to frequency after 24 hours warm-up)

Temperature characteristics: ²5 x 10–8 (0° to 50°C, referred to frequency at 25°C)

External standard input: 10 MHz or 13 MHz (±1 ppm), input level: 2 to 5 Vp-p

Power meter

Frequency range: 300 kHz to 3 GHz

Level range: 0 to +40 dBm

Measurement accuracy: ±10% (after zero point calibration)

Signal generator

Frequency

Range: 300 kHz to 3 GHz

Resolution: 1 Hz

Accuracy: Reference frequency accuracy ±100 mHz

Output level

Setting range: –143 to –28 dBm (MAIN connector), –143 to –3 dBm (AUX connector)

Level accuracy: ±1.5 dB (10 MHz to 1 GHz, ³–123 dBm), ±3 dB (10 MHz to 1 GHz, ³–133 dBm),

±2 dB (>1 GHz, ³–123 dBm), ±4 dB (>1 GHz, ³–133 dBm)

Radiated interference:

1 μV/50 ½ (carrier frequency measured, 25 mm from front panel with two-turn 25 mm diameter loop antenna)

Signal purity

Spurious: ²–50 dBc (at CW, offset frequency 100 kHz to ²50 MHz; where carrier frequency: other than 1300 MHz to

1400 MHz and 2000 MHz to 2100 MHz), ²–40 dBc (for all band)

Harmonics: ²–25 dBc (at CW)

Others

Display: Color TFT-LCD, 7.8 inches, 640 x 480 dots

Hard copy:

Enables data hard copy of the display through a parallel interface (applicable only for EPSON VP series or equivalent)

GPIB: This equipment is specified as a device, can be controlled from external controller (excluding power switch and FD

ejection key). No controller function

Interface: SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, C0, E2)

Parallel

Conform to the Centronics. Outputs printing data to printer. Data line exclusive for output: 8

Control line: 4 (BUSY, DTSB, ERROR, PE)

Connectors: D-sub 25 pins, female (equivalent to the connector of IBM-PC/AT built-in printer)

RS-232C: All functions except power switch controlled by external controller (baud rate: 1200, 2400, 4800, 9600 bps)

Dimensions and mass

426 (W) x 221.5 (H) x 451 (D) mm, ²22 kg

Power

100 to 120/200 to 240 Vac (automatic voltage switch system), 47.5 to 63 Hz, ²300 VA

Operating temperature

0° to 50°C

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E