Products
- Amplifier
- Analyzer
- Antenna
- Automotive EMC
- Cable Fault Locator
- Calibrator
- Chamber / Oven
- Coupling / Decoupling (CDN)
- Curve Tracer
- Data Acquisition
- Electronic Load
- EMC / EMI
- Environmental
- ESD Simulator
- Generator
- GTEM / TEM Cell
- Harmonics & Flicker
- Hipot
- LISN
- Mains Dips & Drops
- Meter
- Oscilloscope
- PIM Test Solution
- Power Supply
- RF Field Monitor System
- Thermostream
Featured Products
California Instruments MX135-3 High Output AC Power Source 135kVA
IFI T4026-50 High Power TWT Amplifier 26.5 GHz – 40 GHz 50W
IFI T2618-50 High Power TWT Amplifier 18 GHz – 26.5 GHz 50W
IFI TCCX2500 Tetrode Tube RF Amplifier 10 kHz – 220 MHz 2500W
California Instruments MX45-3 High Output AC Power Source 45kVA
IFI M406 Tetrode Tube RF Amplifier 10 kHz – 220 MHz 1000W
Amplifier Research FM7004 Electric & Magnetic Field System
Description
The AR RF/Microwave Instrumentation Model FM7004 is a versatile electric and magnetic field monitoring system which performs all measurement display and control functions for field related testing. The FM7004 accepts inputs from up to 4 isotropic Field Probes which are all sold separately to match the test application.
The FM7004 field monitor provides four digital interfaces (IEEE-488, USB, RS-232, and Ethernet) and a highly readable, user configurable, graphic Liquid Crystal Display. The monitor is menu driven and can be controlled from the front panel or remotely through any of the interfaces. The FM7004 displays up to four probe readings simultaneously, in any combination of the �E" field or "H" field 7000 series probes. Readings from each axis, plus the composite reading, are displayed simultaneously.
The FM7004 recognizes each attached 7000 series probe (FP, FH, FL, PL) and automatically displays the proper decimal places and units. Any faults that occur will be logged and the unit is programmed to be self correcting when possible. As software driven instrument, field monitor software upgrades can be made through the USB port.
The isotropic field probes have an integral optical transceiver which communicates with the field monitor through a twin fiber optic cable. The operator can select minimum, maximum or average reading from any or all selected probes thus enjoying complete flexibility in choice of signal input. Minimum and maximum hold capability has also been incorporated with local or remote controlled start and stop.
The FM7004 has the ability to correct probe readings over frequency using a set of correction factors stored in its internal memory. The FM7004 allows for up to six tables of field probe correction factors to be stored. One table of correction factors can contain up to 30 different frequency points. The tables are loaded on the FM7004 using the USB port and the Table Loader program.
Features
Specifications
Sensitivity |
0.4–1000 V/m (probe dependent) 12.0 mA/m–17 A/m (probe dependent) |
|
Frequency response |
5 kHz - 60 GHz (probe dependent) |
|
Inputs |
Up to 4 independent probes, through 4 F/O FSMA pairs |
|
Overload withstand |
Probe dependent |
|
Output |
graphical, color LCD digital display, resolution 0.01 IEEE-488 interface USB 2.0 (test and measurement class) RS-232 interface (19200 Baud) Ethernet |
|
Sample Rate |
Probe dependent |
|
Power requirements |
Input voltage Universal input 90 - 260 VAC, 50-60 Hz |
|
Input current 0.2 - 0.6 Amps |
||
Input type IEC Inlet with filter |
||
Fuse 1A, 5x20 mm slow blow |
||
Operating temperature range |
10 – 40 C (50 – 104 F) @ 5 - 95% RH non-condensing |
|
Enclosure |
Desktop case, 2U high |
|
Correction factor tables |
Number of tables |
Stores up to 6 different tables (each table corresponding to one probe) |
Frequency points per table |
2 to 30 |
|
Weight |
Without enclosure 2.3 kg (5 lb) |
|
With enclosure 6.7 kg (14.75 lb) |
||
Dimensions |
Without enclosure 48.3 x 9.0 x 25.4 cm (9 x 3.5 x 10 in) |
|
With enclosure 49.8 x 12.7 x 30.5 cm (19.6 x 5.0 x 12.0 in) |
Suited Probes
Model |
Description |
FP7003/Kit |
Isotropic "E" Field Probe, 100 kHz - 3 GHz, 0.4 - 660 V/m |
FP7018/Kit |
Isotropic "E" Field Probe, 3 MHz - 18 GHz, 0.6 - 1000 V/m |
FP7050/Kit |
Isotropic "E" Field Probe, 300 MHz - 50 GHz, 8 - 614 V/m (thermocouple for radar pulses) |
FP7060/Kit |
Isotropic "E" Field Probe, 100 MHz - 60 GHz, 0.7 - 300 V/m |
FH7110/Kit |
Isotropic "H" Field Probe, 27 MHz - 1 GHz, 0.025 - 16 A/m |
FL7030 |
Electric Field Laser Powered Probe, 5 kHz - 30 MHz, 0.5 - 300 V/m |
FL7030CC |
Electric Field Probe with Custom Calibration, 5 kHz - 30 MHz, 1.5 - 300 V/m |
FL7030/Kit |
Electric Field Laser Powered Probe Kit, 5 kHz - 30 MHz, 0.5 - 300 V/m (includes the FI7000 probe interface, 10 meter glass cable and carrying case) |
FL7006 |
Electric Field Laser Powered probe, 100 kHz - 6 GHz, 0.5 - 800 V/m |
FL7006CC |
Electric Field Probe with Custom Calibration, 100 kHz - 6 GHz, 0.5 - 800 V/m |
FL7006/Kit |
Electric Field Laser Powered Probe Kit, 100 kHz - 6 GHz, 0.5 - 800 V/m (includes the FI7000 probe interface, 10 meter glass cable and carrying case) |
FL7218 |
Electric Field Laser Powered Probe, 2 MHz - 18 GHz, 2 - 1000 V/m (probe only) |
FL7218/KIt |
Electric Field Laser Powered Probe Kit, 2 MHz - 18 GHz, 2 - 1000 V/m |
FL7040 |
Electric Field Laser Powered Probe, 2 MHz - 40 GHz, 2 - 1000 V/m (probe only) |
FL7040CC |
Electric Field Probe with Custom Calibration, 2 MHz - 40 GHz, 2 - 1000 V/m |
FL7040/Kit |
Electric Field Laser Powered Probe Kit, 2 MHz - 40 GHz, 2 - 1000 V/m (includes the FI7000 probe interface, 10 meter glass cable and carrying case) |
FL7060 |
Electric Field Laser Powered Probe, 2 MHz - 60 GHz, 2 - 1000 V/m |
FL7060/Kit |
Electric Field Laser Powered Probe Kit, 2 MHz - 60 GHz, 2 - 1000 V/m (includes the FI7000 probe interface, 10 meter glass cable and carrying case) |
PL7004 |
Electric Field Pulse Laser Powered Probe 800 MHz - 3.6 GHz, 80 - 800 V/m |
PL7004/Kit |
Electric Field Pulse Laser Powered Probe Kit, 800 MHz - 3.6 GHz, 80 - 800 V/m (Includes the FI7000 probe interface, 10 meter glass cable and carrying case) |
FM7004A |
Field Monitor, 0.4 - 1000 V/m, 12.0 mA/m - 17 A/m Sensitivity. Accepts inputs from up to 4 isotropic Field Probes |
VM7000 |
Virtual Instrument Field Monitor Software for use with all FP7xxx and FHxxx probes and computer. Model IF7000 required. |
VM7000SC |
Virtual Field Monitor Service Contract - available after first year. Free upgrades and drivers helpline included. |
MP00030A |
FM7004 field monitor and FL7030/Kit Laser Powered probe package |
MP06000A |
FM7004 field monitor and FL7006/kit Laser Powered probe kit package |
MP06001A |
FM7004 Field Monitor and FL7006/Kit and FL7030/Kit Laser Powered probe kit package |
MP18000B |
FM7004 Field monitor, FL7030/Kit and FL7218/Kit Laser powered probe kit package |
MP18001A |
FM7004 field monitor and FL7218/Kit Laser Powered Probe kit package |
MP40000A |
FM7004 field monitor, FL7030/Kit and FL7040/Kit laser power probe kit package |
MP40001A |
FM7004 field monitor and FL7040/Kit laser powered probe package |
MP60000B |
FM7004 field monitor, FL7030/Kit and FL7060/Kit Laser Powered probe kit package |
FI7000 |
Probe Interface |
BC7000 |
Fast Charger, single probe for all FP7xxx and FH7xxx series probes |
PS2000A |
Probe Stand, adjustable to 7.5 feet |
CL2000 |
Probe Clamp, extra clamp for PS2000 |
FT2000 |
Bulkhead Feedthrough Set, SMA Connectors |
FC2010 |
Fiberoptic Transmit/Receive Glass Cable Set, 10 meters, SMA connectors |
FC2050 |
Fiberoptic Transmit/Receive Glass Cable set, 50 meters, SMA connectors |
FC2100 |
Fiberoptic Transmit/Receive Glass Cable Set, 100 meters, SMA Connectors |
IF7000 |
Fiberoptic/RS-232 Interface, SMA Connectors |
IF7001 |
Fiberoptic/USB Inteface, SMA Connectors |
MA7000 |
Fiberoptic Mating Adapter Set |
FC7010 |
Fiberoptic Cable set for the FL7000 series probes and kits, 10 meters |
FC7020 |
Fiberoptic Cable set for the FL7000 series probes and kits, 20 meters |
FC7050 |
Fiberoptic Cable set for the FL7000 series probes and kits, 50 meters |
FC7100 |
Fiberoptic Cable set for the FL7000 series probes and kits, 100 meters |
Standards
CISPR |
CISPR 11 |
CISPR 14 - 1 |
CISPR 14 - 2 |
CISPR 14 - 2 |
CISPR 16 - 1 |
CISPR 16 - 2 |
CISPR 16 - 3 |
CISPR 16 - 4 |
CISPR 22 |
CISPR 24 |
IEC |
IEC/TR EN 61000 - 1 - 1 |
IEC/TR EN 61000 - 2 - 1 |
IEC/TR EN 61000 - 2 - 3 |
IEC EN 61000 - 3 - 2 |
IEC EN 61000 - 3 - 4 |
IEC/TC EN 61000 - 3 - 5 |
IEC EN 61000 - 4 - 2 |
IEC EN 61000 - 4 - 3 |
IEC EN 61000 - 4 - 4 |
IEC EN 61000 - 4 - 5 |
IEC EN 61000 - 4 - 6 |
IEC EN 61000 - 4 - 7 |
IEC EN 61000 - 4 - 8 |
IEC EN 61000 - 4 - 9 |
IEC EN 61000 - 4 - 11 |
European |
EN 50 081 part 1 |
EN 50 081 part 2 |
EN 55 011 |
EN 55 013 |
EN 55 014 |
EN 55 015 |
EN 55 020 |
EN 55 022 |
EN 55 024 |
EN 50 082 part 1 |
EN 50 082 part 2 |
EN 50 093 |
American |
FCC Part 15 |
MIL-STD - 461E |