Amplifier Research FL7030 Electric Field Probe 5 kHz - 30 MHz 300V/m

Description

Amplifier Research FL7030 is a smart, fast, extremely accurate electric field probe that contains an internal microprocessor to provide linearization, temperature compensation, control, and communication functions. Noise reduction and temperature compensation allow accurate measurements down to 1.5 V/m without zero adjustment. When rotated about its critical angle mount, the probe provides isotropic response of ±0.5 dB over its specified frequency range.

The FL7030 is laser powered to allow for continuous operation without battery recharging or replacement.

Correction factors are provided with the probe. These factors can be loaded into the Model FM7004 Field Monitor (sold separately) to automatically correct the probe readings at user-specified frequencies. When correction factors are applied, the true accuracy of the probe can be realized.

It communicates and is powered through glass fiber optic cables, up to 100 meters long, to the FI7000 interface. X, Y, Z, and isotropic readings can be returned through an FI7000 in 20 msec.

The FL7030 extends the range of AR laser powered E–field probes down to 5 kHz. It offers an extended post–detection response-smoothing time constant to provide more consistent readings for carrier frequencies down to 5 kHz.

Features

  • Broad frequency range
  • Contains an internal microprocessor that enables them to “think” for themselves and adapt to their environment
  • Provides optimal linearization, temperature compensation, control and communication functions
  • Because they’re laser powered, you never have to change or replace batteries 
  • Ruggedized antenna cones and fiber optic cables provide unequalled reliability

Specifications

Amplitude Accuracy (field aligned with sensor axes)

Without correction factors applied

±1.0 dB @ 10 MHz

With correction factors applied

Typical expanded measurement uncertainty (95% confidence interval)

0.8 dB, 5 kHz–30 MHz

Response Time/Sampling Rate (through FI7000)

20 msec/up to 50 samples per second,  at FI7000 USB and GPIB interfaces

Response smoothing time constant

10 msec nominal

Isotropic Deviation (measured at the critical angle)

± 0.5 dB @ 10 MHz

± 0.5 dB, 5 kHz–30 MHz (typical)

Operating Range

1.5–300 V/m

Linearity, 1.5 to 300 V/m

± 0.5 dB and ± 0.9 V/m

Temperature Stability

± 0.5 dB over operating temperature range

Damage Level

1000 V/m continuous field

Ranges

Single range

Data returned from probe

X, Y, Z axes, and composite

Power Requirements

Laser powered from FI7000 interface

Dimensions

5.7 x 5.7 x 5.7 cm (2.25 x 2.25 x 2.25 in)

2.92 cm (1.15 in) DIA spherical housing

3.18 cm (1.25 in) sensor radome per axes

Weight

62.5 g (2.2 oz)

Operating Temperature Range

10˚C to 40˚C (50˚F to 104˚F) @ 5% to 95% RH non-condensing

Fiber Optic Connectors

Two E2000 compact duplex connectors at 1 meter, includes fiber optic verification loop.

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E