AC Specifications
|
Standard
|
Ohms
|
PEAK OUTPUT
|
RMS OUTPUT
|
40mSec Pulse, 20% Duty Cycle
|
5 Min, 100% Duty Cycle
|
1 Hr, 100% Duty Cycle
|
5 Min, 100% Duty Cycle
|
1 Hr, 100% Duty Cycle
|
Volts
|
Amps
|
Volts
|
Amps
|
Volts
|
Amps
|
Volts
|
Amps
|
Volts
|
Amps
|
Watts
|
open
|
200
|
0
|
200
|
0
|
200
|
0
|
141
|
0
|
141
|
0
|
0
|
16
|
195
|
12
|
195
|
12
|
195
|
12
|
138
|
8
|
138
|
8
|
1170
|
8
|
183
|
23
|
183
|
23
|
183
|
23
|
129
|
16
|
129
|
16
|
2104
|
4
|
165
|
41
|
165
|
41
|
165
|
41
|
117
|
29
|
117
|
29
|
3381
|
2
|
150
|
75
|
|
|
86
|
43
|
0
|
0
|
61
|
30
|
1848
|
1.5
|
134
|
90
|
|
1
|
116
|
105
|
|
0.5
|
66
|
112
|
|
Optional High-Current (HC) Version
|
Ohms
|
PEAK OUTPUT
|
RMS OUTPUT
|
40mSec Pulse, 20% Duty Cycle
|
5 Min, 100% Duty Cycle
|
1 Hr, 100% Duty Cycle
|
5 Min, 100% Duty Cycle
|
1 Hr, 100% Duty Cycle
|
Volts
|
Amps
|
Volts
|
Amps
|
Volts
|
Amps
|
Volts
|
Amps
|
Volts
|
Amps
|
Watts
|
2
|
55
|
39
|
55
|
28
|
55
|
28
|
39
|
20
|
39
|
20
|
770
|
1
|
51
|
36
|
51
|
51
|
48
|
48
|
36
|
36
|
34
|
34
|
1152
|
0.5
|
26
|
52
|
26
|
52
|
26
|
52
|
18
|
37
|
18
|
37
|
676
|
AC Specification
|
Frequency Response
|
DC – 30 kHz, +0.1, –0.5 dB
|
8 ohm Power Response
|
DC-40 kHz
|
± 180 Vpk
|
DC-50 kHz
|
± 150 Vpk
|
DC-150 kHz
|
± 50 Vpk
|
DC-200 kHz
|
± 25 Vpk
|
Maximum Continuous Output Power
|
3300 watts RMS
|
Power Sinking
|
1.2 kVA at 120VAC
|
Slew Rate
|
41 V/μSec
|
Phase Response
|
± 5 degrees (10 Hz - 10 kHz)
|
Unit to Unit Phase Error
|
+/- 0.1 degrees at 60Hz
|
Output Offset:
|
7548
|
Less than 5 mV, field adjustable to less than 1 mV
|
7548P
|
Less than 200 μV
|
Output Offset Current
|
Less than 10 mill amperes DC
|
DC Drift
|
7548
|
±1.5 mV
|
7548P
|
± 400 μV (from cold to maximum operating temperature); ±200 μV (after 20 minutes of operation)
|
Residual Noise
|
Unfiltered
|
Less than 75 μV
|
|
Filtered
|
(400 Hz – 30 kHz): Less than 55 μV
|
THD
|
DC - 30 kHz less than 0.1%
|
Input Characteristics
|
Balanced with ground
|
Three terminal barrier block connector 20 k ohm differential
|
Unbalanced
|
BNC connector, 10 k ohm single ended
|
Gain
|
Voltage Mode
|
20 volts/volt
|
|
Current Mode
|
20 amperes/volt
|
Max Input Voltage
|
± 10 V balanced or unbalanced
|
Input Impedance
|
20 kOhm differential
|
Input Sensitivity
|
3.0V input for 3800W output into 1 ohm (adjustable)
|
Common Mode Rejection Range
|
± 11 VDC maximum
|
Common Mode Rejection Ratio
|
70 dB
|
Display, Control, Status, I/O
|
Front Panel LED Displays indicate
|
Run, Ready, Standby, Stop, and Fault conditions in the output stage
|
LCD Display
|
Lists type of fault condition and gives suggested corrective action
|
Soft Touch Switches for
|
Run (Enable), Stop, Reset
|
User Configurable
|
LCD display can be configured for up to four simultaneous displays reporting one, two or all four of the following: Voltage Peak, Voltage RMS, Current Peak, and Current RMS
|
Back Panel
|
Power Connection
|
NEMA-style locking receptacle; matching AC connector also included
|
Signal Output
|
4-position terminal barrier block
|
Signal Input
|
User-selectable Unbalanced BNC or Balanced Barrier Strip
|
Interlock Connector
|
25-pin D-sub connector used for amplifier control and status applications; also used in multi-amplifier applications
|
Communication Capabilities
|
Current Monitor
|
± 1V / 20A ±1%
|
Voltage Monitor
|
± 1V / 1V ±1%
|
Reporting
|
System Fault, OverTemp, Over Voltage, Overload
|
Control
|
Force to Standby; Reset after a fault
|
Protection
|
Over/Under Voltage
|
± 10% from specified supply voltage amplifier is forced to Standby
|
Over Current
|
Breaker protection on both main power and low voltage supplies
|
Over Temperature
|
Separate Output transistor, heat sink, and transformer temperature monitoring and protection
|
Physical Characteristics
|
Chassis
|
Black powder-coat chassis with all aluminum construction; designed for stand-alone or rack-mounted operation. The amplifier occupies five EIA 19-inch-wide rack units
|
Weight
|
103 lbs. (46.7 kg)
|
AC Power
|
Three-phase, 208 VAC ±10%, 47-60 Hz, 20A AC service (400 VAC ±10%, 15A version available). A toggle switch circuit breaker opens all legs of the AC mains on excess current demand.
|
Operating Temperature
|
10°C to 50°C (50°F to 122°F), Maximum Output Power de-rated above 30°C (86°F)
|
Humidity
|
70% or less, non-condensing
|
Cooling
|
Forced air-cooling from front to back through removable filters via four 100 ft3/min. fans. No space is required between rack-mounted amplifiers. Air filters are removable from the rear via one fastener per side and may be eliminated if cabinet filtration is provided.
|
Dimensions
|
19 in. x 22.8 in. x 8.75 in. (48.3 cm x 57.9 cm x 22.3 cm). Unit occupies five EIA 19-inch-wide rack units.
|