»  Categories   »      Harmonics & Flicker   »    EMC / EMI   »    Power Quality Analyzer   »    Analyzer  

image enlarge

TESEQ ProfLine 2105 Single Phase Harmonics & Flicker System 5 kVA

Description

System
ProfLine 2105 is an accurate and flexible single phase system designed to measure harmonics and flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3, supporting testing on products consuming up to 11 Amps rms and 92 Amp peak @230 Vac. The system is supplied complete with a stable, accurate, programmable 3 kVA power source. The ProfLine 2105 system is therefore ready to measure and record any harmonics and flicker created by the EUT. A wide range of higher power AC source systems are available from Teseq, please see ProfLine 2103, 2115, 2130, 2145 datasheets for suitable systems at higher power or for 3-phase operation.

Measurements are made using precision, no burden, and active hall-effect current transformers connected via a dedicated cable to a multichannel fast Data Acquisition Card (DAQ) fitted inside a PC. One voltage and three current measuring channels are used to make simultaneous measurement of both current and voltage. Calculations are made using dedicated Teseq software (WIN 2100) to determine harmonics (classes A-D), inter-harmonics, flicker, dc, dt, dmax, Pst, Plt, inrush current and 24 x dmax.

Impedance
Measurement of flicker requires a fixed, stable source impedance as specified in IEC 61000-3-3 (0.24 Ω+ j0.15 Ω in the line and 0.16 Ω + j0.1 Ω in the neutral). The precision power source (NSG 1007-3) supplied as part of the system is able to accurately simulate this impedance by careful control of the relationship between voltage and current. This eliminates the need for costly physical impedance. However, hardware lumped impedances are available from Teseq, see options list.

Power quality measurement
The power source (NSG 1007-5) supplied as part of the ProfLine 2103 system is able to perform tests in conformance to a number of immunity standards. IEC 61000-4-13 (immunity to harmonics and interharmonics), IEC 61000-4-14 (voltage fluctuations), IEC 61000-4-17 (ripple on DC) and IEC 61000-4-28 (variation of power frequency). Additionally it can also perform pre-compliance testing to IEC 61000-4-29 (voltage dips, interrupts and variations on DC supply) and IEC 61000-4-11. With the addition of further options IEC 61000-4-8 (power frequency magnetic) and fully compliant IEC 61000-4-11 (voltage dips, interrupts and variation on AC supply) can be implemented.

Features

  • Complete test system for IEC 61000-3-2 and -3-3
  • Single phase system up to 16 Amps
  • Simulated flicker impedance, no need for expensive physical impedance
  • Power source suitable for testing to immunity standards

Specifications

Mains supply options

ProfLine 2105-208

ProfLine 2105-400

System contents

NSG 1007-5-208 Power source         NSG 1007-5-400 Power source

 CCN 1000-1 1-phase                           CCN 1000-1 1-phase

coupling unit                                         coupling unit

DAQ card                                               DAQ card

Interface cable                                     Interface cable

WIN 2100 H&F test software            WIN 2110 PQT test software

WIN 2100 H&F test software            WIN 2110 PQT test software

 Pre-configured PC                              Pre-configured PC

USB cable                                              USB cable

Power source (for full specification see separate datasheet)

Power output (AC mode)

5,000 VA

5,000 VA

Voltage AC, two ranges

0-150 V and 0-300 V

0-150 V and 0-300 V

Maximum current (low range)

37.0 Amps, 110 Amps

37.0 Amps, 110 Amps

peak repetitive

peak repetitive

Maximum current (high range)

18.5 Amps, 96 Amps

18.5 Amps, 96 Amps

peak repetitive

peak repetitive

Frequency range (AC mode)

16 – 1000 Hz

16 – 1000 Hz

Power output (DC mode)

3,500 watts

3,500 watts

Voltage DC, two ranges

0-200 V and 0-400 V

0-200 V and 0-400 V

Maximum current (low range)

26.0 Amps

26.0 Amps

Maximum current (high range)

13.0 Amps

13.0 Amps

Supply

3-phase, 208 Vac L-L, 50/60 Hz

3-phase, 400 Vac L-L, 50/60 Hz

Dimensions (HxWxD)

178 x 483 x 610 mm

178 x 483 x 610 mm

Weight

28 kg

28 kg

Coupling unit

Number of phases

1

1

Measurement channels

4

1

2

EUT connector: Front panel

CEE 77

CEE77

EUT connector: Rear panel

Terminal block

Terminal block

Maximum voltage: Front panel

240 Vac

240 Vac

Maximum current: Front panel

16 Arms

16 Arms

Maximum voltage: Rear panel

300 Vac

300 Vac

Maximum current: Rear panel

40 Arms (200 A Pk for 10 ms)

40 Arms (200 A Pk for 10 ms)

Supply power: Voltage

115/230 Vac +/- 10%

115/230 Vac +/- 10%

Supply power: Current

<0.5 A

<0.5 A

Supply power: Frequency

50/60 Hz

50/60 Hz

Dimensions (HxWxD)

89 x 427 x 560 mm

89 x 427 x 560 mm

Weight

5 kg

5 kg

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E