Description

The three-phase coupling/decoupling networks of the CNI 503x series are used to couple EFT/Burst pulses and Surge pulses on DC-lines or to three-phase (4-wire or 5-wire supply lines) mains supply systems for voltages up to 1,000VDC / 3x690VAC. This includes the more and more common testing of inverters used in the area of renewable energies (e.g. photovoltaic systems, wind power stations, electric cars).

The CNI 503x-series coupling/decoupling networks are built fully complying to the standard requirements of EN/IEC 61000-4-4 and EN/IEC 61000-4-5. Residual voltage levels are carefully considered as well as the value of the decoupling inductors in order to meet the requirements with regard to voltage drop at the rated current of each type of CDN. Apart from the coverage of the EN/IEC 61000-4-5 standard the CNI 503Bx series also fully complies with the surge test requirements outlined in ANSI/IEEE C62.41.

Being fully controlled by the related generators couplings of the CNI 503x are set automatically as selected for the test (either by manual operation or via software). When performing surge tests the generators will automatically set the required source impedance depending on the standard and the coupling mode.

Features

  • Combined coupler for EFT/Burst and Surge
  • Surge as per ANSI/IEEE C62.41 (models CNI 503Bx only, other couplers on request)
  • LEDs indicate active mode and coupling
  • Automatic selection of Surge impedance
  • Fully remote controlled by EM TEST generators
  • Meet requirements for 3x690VAC and 1,000VDC

Specifications

MODEL OVERVIEW

AVAILABLE CNI 503X-MODELS UP TO 5.5KV

CNI 503A

3x480V, 16A AC

CNI 503A S1

3x690V, 16A AC

CNI 503A2

3x480V, 32A AC

CNI 503A S2

3x690V, 32A AC

CNI 503A3

3x480V, 63A AC

CNI 503A S3

3x690V, 63A AC

CNI 503A4

3x480V, 100A AC

CNI 503A S4

3x690V, 100A AC

AVAILABLE CNI 503X-MODELS UP TO 7KV

CNI 503B5

3x480V, 16A AC

CNI 503B S1

3x690V, 16A AC

CNI 503B7

3x480V, 32A AC

CNI 503B7.3

3x480V, 32A AC

1,000V, 32A DC

CNI 503B7.5

3x690V, 32A AC

1,000V, 32A DC

CNI 503B S2

3x690V, 32A AC

CNI 503B8

3x480V, 63A AC

CNI 503B S3

3x690V, 63A AC

CNI 503B9

3x480V, 100A AC

CNI 503B9.2

3x480V, 100A AC

1,000V, 100A DC

CNI 503B9.4

3x690V, 100A AC

1,000V, 100A DC

CNI 503B S4

3x690V, 100A AC

AVAILABLE CNI 503X-MODELS UP TO 8KV

CNI 503A10

3x480V, 16A AC

CNI 503A12

3x480V, 32A AC

CNI 503A13

3x480V, 63A AC

CNI 503A14

3x480V, 100A AC

AVAILABLE CNI 503X-MODELS UP TO 10KV

CNI 503A16

3x480V, 16A AC

CNI 503A18

3x480V, 32A AC

CNI 503A19

3x480V, 63A AC

CNI 503A20

3x480V, 100A AC

GENERAL DATA

COUPLING MODES

IEC 61000-4-4

Line(s) to Reference Ground; all combinations

IEC 61000-4-5

Line to Line with a 2ohm source impedance

Line(s) to PE with a 12ohm source impedance

ANSI/IEEE C62.4

 (supporting models only)

Surge coupling with a 2ohm source impedance for all lines

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093