XFR 1.2kW General Specifications
|
Operational AC Input Voltage
|
85-130VAC or 190-264VAC, 1 phase (17 @ 120VAC; 8.8A @ 230VAC typical), 47-63Hz
|
Switching Frequency
|
Nominal 78kHz (156kHz output ripple)
|
Time Delay
|
7s maximum from power on until output stable
|
Voltage Mode Transient Response Time
|
3ms for output voltage to recover within 0.5% of its previous level after a step change in load current of up to 10% to 90% of rated output
|
Maximum Voltage Differential
|
±600VDC from output to safety ground
|
Remote Start/Stop and Interlock
|
TTL-compatible input, selectable logic
|
Remote Analog Programming
|
Voltage and current programming inputs (source must be isolated): 0-5k, 0-10k resistances; 0-5V (default), 0-10V voltage sources
|
Remote Analog Monitoring
|
Voltage/ current monitor outputs 0-5V, 01-10V ranges for 0-100% of output
|
Remote Programming and Monitoring Accuracy
|
<1% of full scale output for the default range
|
Maximum Remote Sense Line Drop Compensation
|
5V/line (Line drop is subtracted from total voltage available at supply output)
|
Operating Temp. Range
|
0 to 50°C
|
Storage Temperature Range
|
–40 to 85°C
|
Humidity Range
|
0 to 80% RH, non-condensing
|
Front Panel Voltage and Current Control
|
10-turn voltage and current potentiometers
|
Front Panel Voltage Control Resolution
|
0.02% of maximum voltage
|
AC Input Connector Type
|
3-Terminal, 34A/250V, wire clamp connector with strain relief cover
|
Main Output Connector
|
7.5 to 40V models: nickel-plated copper bus bars with bus bar cover; 60V to 600V models: 4-terminal wire clamp connector with strain relief
|
Weight
|
Approximately 8.2kg (18 lb)
|
Approvals
|
CE-marked, units meet IEC 1010-1 safety standard, and EN50081-2 and EN50082-1 EMC standards. Additional standards: CSA C22.2 No. 1010.1, UL 3101, and FCC, part 15, class A EMI standard
|
XFR 1.2kW Options
|
GPIB-XFR
|
GPIB Interface Card (16 Bit)
|
RS-232-XFR
|
RS-232 Interface Card (16 Bit)
|
ISOL-XFR
|
Isolated Interface Card provides isolated analog control and readback of output voltage and current
|
M13
|
Locking Bushings on front panel controls
|