Tenney WSP Air-to-Air Thermal Shock Chamber -75°C to 200°C

Description

Tenney WSP Series Thermal Shock Chambers

The Tenney WSP air-to-air thermal shock chamber is a fully automated dry shock test system capable of taking product from 200 C to -70 C and back in 10 seconds or less. A movable chamber automatically transfers the workload from one temperature chamber to the other.

A dry nitrogen feed system facilitates oxygen purging in the heat chamber, preventing condensation on the metal parts of the chilled workload. A defrost heater is included to periodically defrost the cold chamber during extended tests. The lower chamber uses LN2 to reduce workload temperature.

Features

  • Meets military standards: MIL-STD 202F, Method 107 G, Conditions A, B, C, and F  MIL-STD 883, Method 1010.7, Conditions A, B, C, and F
  • Solid-state overtemperature/ undertemperature protection
  • Electric open-air nichrome wire heater elements supported by ceramic insulators
  • Two open ended finned LN2 cooling coils
  • Centrifugal type blower wheel with external mounted motor
  • Pneumatically activated carriage transport system with up to six stainless steel mesh product baskets
  • Test chamber drain with Type 1/4" FPT connection
  • Door switches for each chamber

Performance

  • Cold Chamber Range: -75° C to  + 200° C,  ± 1.0°  
  • Hot Chamber Range: +40° C to  + 200° C,  ± 1.0°  
  • Total Workspace: 15" W x 15"D x 16"H (Each Chamber)
  • 2.1 Cubic Feet (Each Chamber)
  • Carriage Basket Capacity: 6 baskets; 10"W x 10"D x 1"H

Controller – VersaTenn V

  • Two channel controller
  • Auto/ manual control
  • Pentium class processor
  • 8 MB flash disk on chip storage
  • USB flash disk port
  • RS-232 communications
  • Color LCD touch screen interface with real-time graphic displays
  • Microsoft Windows CE Operating System
  • Logic circuits automatically select cooling and heating modes
  • Near infinite number of programs and steps possible
  • RTD sensors for temperature measurement
  • 2 process inputs, 10 temperature control outputs, 6 event outputs
  • Alarm output for each channel
  • RS232 data communications

Watlow LV Limit Controller

  • Single Channel
  • Profiling: Forty Profiles, 256 Steps
  • Automatic & Manual Control
  • 1 Input: Universal Type (RTD is Std.)
  • 4 Digital Inputs
  • 2 Auxiliary Analog Inputs - Optional
  • 2 Control Outputs: Time Proportioned, On/Off, or 4-20 ma
  • 2 Alarm Outputs
  • 8 Digital Event Outputs
  • 2 Retransmit Outputs - Optional
  • Communications: EIA-232 and EIA-485 with Modbus RTU protocol

Specifications

Model

Chamber Dimensions W x H x D in.

Outer Dimensions W x H x D in.

Input kW

Voltage 60 Hz 1-phase*

Cubic Feet Capacity (liters)

WSP -109-MP3

14x 16 x 14

50-1/2 x 86-3/4 x 46

110

208V

2.0

WSP- 109C-MP3

100

240V

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E