»  Categories   »      Voltage Surge Generator   »    Surge Generator   »    Pulse Generator   »    EFT/Burst Generator   »    Generator  

image enlarge

Haefely PIM 210 8/20µs & 10/1000µs Current Module

Description

The PIM 210 is used for component testing with current impulses.

For testing overvoltage protection elements such as varistors and avalanche breakdown diodes with clamping voltages up to 3kV. Both impulse shapes 8/20µs and 10/1000µs are used in tests according to the IEC and the ANSI standards. These tests include the measurement of the clamping voltage and life span tests with high energies and/or currents. The focus of the PIM 210 is the measurement of the clamping voltage.

For testing components which are exposed to impulse currents such as resistors and electrical contacts. Resistibility tests for telecom equipment exposed to overvoltage and overcurrent can also be performed with the PIM 210.

PSURGE 8000 Surge Platform provides all the programming functions required to perform IEC, ANSI, UL and ITU testing also without the need of a control computer.

The integration in the WinFEAT&R control and reporting software package enhances an efficient setup and operation of this test system. Most importantly, the test load can be transferred to a computer freeing valuable resources.

Features

  • 8/20µs current impulse from 1A up to 1.2kA
  • 10/1000µs current impulse from 1A up to 11A
  • Integrated test cabinet
  • Clamping voltage and peak current display
  • WinFEAT&R software integrated

Applications

  • Protection elements
  • Telecom equipment
  • Measuring the surge impedance of earth systems
  • Many IEC, ANSI, UL & EN Product standards
  • Other international requirements for current impulses

Specifications

Impulse Shape 8/20µs

Impulse front time

I= 8µs ±10%

Impulse duration

I= 20µs ±10%

Current Amplitudes

1A – 1.2kA; UCL=0V

1A – 1kA; UCL=1000V

1A – 800A; UCL=2000V

8A – 650A; UCL=3000V

Repetition @ Umax

5 seconds / 12 per minute

Impulse Shape 10/1000µs

Impulse front time

I= 10µs +20/–10%

Impulse front time

I= 10µs +20/–10%

Current Amplitudes

1A – 11A; UCL=0V

1A – 9A; UCL=1000V

1A – 7A; UCL=2000V

Impulse Polarity

Positive and Negative

Impulse Output

HV terminals inside the test cabinet

Dimensions (W x H x D)

PIM 210

45 x 43 x 57 cm

Test Cabinet

36 x 20 x 32 cm (inside)

Weight

PIM 210

approx. 35 kg (54 lbs)

Note: UCL = clamping voltage of EUT

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E