Haefely PIM 150 100 kHz & 1 MHz Oscillating Wave Module

Description

IEC 61000-4-12 and ANSI C37.90 describe an oscillating wave generator with defined open circuit waveforms parameters. The oscillating wave, also called a damped sine is used to test the immunity of electronic relays and relay systems mounted in an electrical substation or similar harsh environment. IEC product standards such as IEC 60255-22-1 include this wave shape too.

Safety is paramount when AC and impulse voltages are being used. The PIM 150 High Voltage connections are all designed so no accidental contact can occur. In addition, the CDN input and output terminals use touch-proof connectors.

PIM 150 contains an integrated Coupling/Decoupling Network (CDs) for superimposition of the impulse on AC and DC power lines. The integrated CDN is specially designed to ensure wave shape integrity at the test system output. PIM 150 maintains wave shape AND amplitude, even with multiple coupling paths selected.

PIM 150 with the PSURGE 8000 Surge Platform can perform all the programming functions required to perform IEC and ANSI testing without the need of a control computer. Voltage monitor circuits enable quick and easy verification of the impulse shape and amplitude. In addition, peak measurement circuits are used to help determine EUT PASS/FAIL criterion.

The integration in the WinFEAT&R control and reporting software package enhances an efficient set-up and operation of this test system. Most importantly, the test load can be transferred to a computer freeing valuable resources.

Features

  • 100kHz & 1MHz frequencies
  • 75ns rise-time
  • 3.3kV impulse voltage
  • Source Impedance 200 Ohm
  • Integrated three phase CDN
  • Variable burst duration

Applications

  • Single & Three phase power line systems
  • IEC 61000-4-12 Power & Data lines
  • ANSI C37.90.1-2002 Power lines
  • IEC 60255-22-1 Measuring relays and protection equipment
  • IEEE 1613 Substation Equipment

Specifications

Impulse Voltage

0.25 – 3.3kV

Burst Frequency

100kHz & 1MHz

Impulse Repetition

40 Hz & 400Hz

Source Impedance

200 ohms

Burst Duration

2 seconds to continuous

Rise time

75ns

Damping Rate

50% Vpk between 5th and 10th peak

EUT Voltage

480Vac (phase - phase) / 110Vdc

EUT Current

16A ac/dc per path

Impulse Coupling

Single & Multiple Path

Impulse Polarity

Positive, Negative & Alternating

Impulse Output

HV connector & CDN

EUT Safety switch

16A Thermo magnetic

Monitor Output

BNC, volts (500 / 1)

Dimensions (W x H x D)

45 x 20 x 57 cm

Weight

44 lbs (29 kg)

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E