IEC 61000-4-5 and ANSI C62.41 describe a combination Wave or Hybrid generator with defined open AND short circuit waveforms. The Combination Wave is used to test AC and DC power systems.
Safety is paramount with surge impulses. The PIM 100 High Voltage connections are all linked into the System Safety Concept which prevents high voltage plugs or cables from exposing operators to potentially lethal voltages. This concept is extended to Coupling/Decoupling Networks (CDNs) connected to the PIM 100 output.
PIM 100 as part of the PSURGE 8000 Surge Platform System can be used together with Coupling/Decoupling Networks (CDNs) for superimposition of the impulse on AC and DC power lines. Single and three phase CDNs have multiplexed inputs, allowing up to 3 impulse modules to be connected. A full suite of test impulses can then be performed completely automatically and without the need to power down and reconnect the EUT. PSURGE 8000 Surge Platform can perform all the programming functions required to perform IEC and ANSI testing without the need of a control computer. Voltage and Current monitor circuits enable quick and easy verification of the impulse shape and amplitude. In addition, peak measurement circuits are used to help determine EUT PASS/FAIL criterion.
The integration in the WinFEAT&R control and reporting software package enhances an efficient set-up and operation of this test system. Most importantly, the test load can be transferred to a computer freeing valuable resources.
- Floating high voltage output
- Combination wave 1.2/50us - 8/20us
- 7.4kV impulse voltage
- 3.7kA impulse current
- Impulse voltage & current monitors
- Accurate phase angle synchronization
Applications
- Single & Three phase power line systems
- IEC 61000-4-5 Edition 1 and 2 Power & Data lines
- ANSI C62.41 Power lines
- Many IEC & EN Product standards
- Other international requirements for Hybrid impulses
Impulse Voltage
|
0.20 – 7.4kV ±10%
|
Impulse Current
|
0.10 – 3.7kA ±10%
|
Source Impedance
|
2 Ohms
|
Repetition @ Umax
|
10 seconds / 6 per minute
|
Line Synchronization
|
1° steps ±1° @50Hz
|
Impulse front time
|
V= 1.2us ±30% & I= 8us ±20%
|
Impulse duration
|
V= 50us ±20% & I= 20us ±20%
|
Monitor Outputs
|
BNC, volts(750/1) current(400A/V)
|
Impulse Polarity
|
Positive and Negative
|
Impulse Output
|
HV connector with safety circuit
|
Dimensions (W x H x D)
|
45 x 20 x 57 cm
|
Weight
|
44 lbs (29 kg)
|
Standards
CISPR 11 |
CISPR 14 - 1 |
CISPR 14 - 2 |
CISPR 14 - 2 |
CISPR 16 - 1 |
CISPR 16 - 2 |
CISPR 16 - 3 |
CISPR 16 - 4 |
CISPR 22 |
CISPR 24 |
IEC/TR EN 61000 - 1 - 1 |
IEC/TR EN 61000 - 2 - 1 |
IEC/TR EN 61000 - 2 - 3 |
IEC EN 61000 - 3 - 2 |
IEC EN 61000 - 3 - 4 |
IEC/TC EN 61000 - 3 - 5 |
IEC EN 61000 - 4 - 2 |
IEC EN 61000 - 4 - 3 |
IEC EN 61000 - 4 - 4 |
IEC EN 61000 - 4 - 5 |
IEC EN 61000 - 4 - 6 |
IEC EN 61000 - 4 - 7 |
IEC EN 61000 - 4 - 8 |
IEC EN 61000 - 4 - 9 |
IEC EN 61000 - 4 - 11 |
EN 50 081 part 1 |
EN 50 081 part 2 |
EN 55 011 |
EN 55 013 |
EN 55 014 |
EN 55 015 |
EN 55 020 |
EN 55 022 |
EN 55 024 |
EN 50 082 part 1 |
EN 50 082 part 2 |
EN 50 093 |
FCC Part 15 |
MIL-STD - 461E |
|