»  Categories   »      CDN   »    EMC / EMI   »    Coupling / Decoupling (CDN)  

image enlarge

Haefely PCD 121 Coupling Network Symmetrical Data & Control Lines

Description

The PCD 121 is used for coupling of 1, 2/50us - 8/20us combination wave impulses up to 6.6kV peak onto unshielded symmetrical data and signal lines according IEC/EN standards. Up to 2 pairs / 4 wires can be tested simultaneously.

To obtain maximum flexibility only coupling elements are included in the PCD 121. Decoupling circuits, which depends on the EUT to be tested, can be placed separately in the test setup.

It is capable of manual coupling path switching for common mode (longitudinal, line to earth) as well as differential mode (transversal, line to line) testing.

Default coupling elements are gas arrestors and breakdown avalanche diodes. The coupling elements can be selected easily. The direct coupling output allows the customer to use his own coupling elements.

The PCD 121 can be used together with the impulse modules PIM 100 from the Surge Platform and the impulse generator PSURGE 4010. These provide all the programming functions required to perform IEC, ANSI and EN testing also without the need of a control computer.

Features

  • Combination wave 1,2/50us - 8/20us impulse
  • Serial resistors included
  • Up to 2 pairs / 4 wires can be tested
  • Signal Bandwidth up to >10MHz
  • Low capacitive load on the EUT lines
  • Manual coupling path selection
  • Specifically designed to meet and exceed the requirements of:
    • IEC / EN 61000-4-5 Edition 1 Figure 12
    • IEC / EN 61000-4-5 Edition 2 Figure 14

 Applications

  • Unshielded symmetrical data and signal lines
  • Industrial equipment
  • Other international requirements for combination wave impulses on symmetrical operated lines

Specifications

Impulse shape

Combination wave 1,2/50ms-8/20ms

impulse shape defined at the generator output only

Impulse amplitude

max. 6.6kV

Serial Resistor

4 x 40 Ohm

1 wire

 4 x 80 Ohm

2 wires / 1 pair

4 x 160 Ohm

4 wires / 2 pairs

Coupling elements

Gas arrestors 90V

Avalanche breakdown diodes (ABDs)

Voltage on EUT lines

max. 72VDC or 50VAC,RMS 

with gas arrestors as coupling elements

max. 144VDC or 100VAC,RMS

with ABDs as coupling elements

Signal bandwidth

up to >10MHz

with gas arrestors as coupling elements

 

up to >1MHz

with ABDs as coupling elements

Other coupling elements on request.

Weight and Dimensions

Weight

approx. 10 kg net

Dimensions  (w x h x d)

45 x 19.5 x 57 cm

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E