Description

The Fluke DTX Series Cable Analyzers were designed with your time in mind. They significantly reduce the time it takes to certify your network when compared with competitors' analyzers. The Fluke DTX testers will test and certify your CAT 6 cable in 12 seconds. Most other testers take over 30 seconds to perform the same test. This translates to 85 extra certifications before lunch! Not only do these analyzers test for problems, they also suggest potential actions to correct the problem, saving even more troubleshooting time.

The DTX 1200 has a maximum testing bandwidth of 350 MHz, allowing all tests to be done in just 12 seconds in full compliance with industry standards.

The DTX 1800 has a maximum testing bandwidth of 900 MHz, which will allow you to test video distribution, Class F, CATV and 10 Gigabit Ethernet cables.

Unit's internal memory stores up to 250 graphical Cat 6 test results or up to 2000 text reports. In addition each unit includes LinkWare software for link to your PC. Software allows you to edit, view, print, and archive your data. You can then export the data to a PDF.

Features

  • Increase productivity from day one. Intuitive interface means your techs spend less time in training and more time testing
  • Zero to certify in 9 seconds. This unheard-of Cat 6 test speed lets you move from link to link three times faster than with previous testers
  • Level IV Accuracy. Get the most accurate test results in the shortest possible time
  • 350 MHz frequency range. Prepares you for future applications, such as 10 Gigabit Ethernet, Class F and CATV
  • Advanced time-saving diagnostics. Pinpoints the location of a failure and is the only tester that suggests corrective action, saving troubleshooting time
  • Record-fast fiber certification. Certifies a pair of fibers in 9 seconds with DTX single mode and multimode fiber modules
  • 12-hour battery life. Gives you the power to complete any job.
  • Save time managing results. From setup to reporting, LinkWareTCable Test Management Software's simple user interface and time-saving features increase productivity

Specifications

Cable Types

Standard Link
Interface Adapters

Shielded and unshielded Twisted Pair (STP, FTP, SSTP and UTP) LAN cabling:

TIA Category 3, 4, 5, 5E and 6: 100Ω

ISO/IEC Class C and D: 100Ω and 120Ω

ISO/ IEC Class E, 100W ISO/ IEC Class F, 100Ω

Cat 6/ Class E permanent link adapters Plug type and life: shielded and unshielded cable, TIA Cat 3, 4, 5, 5e, and 6 and ISO/IEC Class C, D and E permanent link

Cat 6/Class E channel adapters Plug type and life: shielded and unshielded cable, TIA Cat 3, 4, 5, 5e, and 6 and ISO/IEC Class C, D and E channels

Test Standards

TIA Category 3 and 5e per TIA/EIA-568B

TIA Category 5 (1000BASE-T) per TIA TSB-95

TIA Category 6 per TIA/EIA-568B.2-1 (Addendum #1 to TIA/EIA-568B.2)

ISO/IEC 11801 Class C, D, and E

ISO/IEC 11801 Class F (DTX-1800 only)

EN 50173 Class C, D, E

EN 50173 Class F (DTX-1800 only)

ANSI TP-PMD

IEEE 802.3 10BASE-T, 100BASE-TX, 1000BASE-T

IEEE 802.5 (STP cabling, IBM Type 1, 150Ω ) Token Ring, 4 Mbps and 16 Mbps

Speed of Autotest

Full 2-way Autotest of Category 6 Twisted-Pair links in 12 seconds or less
Full 2-way Autotest of ISO/IEC Class F links in 32 seconds

Supported Tests Parameters

 (The selected test standard determines the test parameters and the frequency range of the tests)

Wire Map
Length
Propagation Delay
Delay Skew
DC Loop Resistance
Insertion Loss (Attenuation)
Return Loss (RL), RL @ Remote
NEXT, NEXT @ Remote
Attenuation-to-crosstalk Ratio (ACR), ACR @ Remote
ELFEXT, ELFEXT @ Remote
Power Sum ELFEXT, PSELFEXT @ Remote
Power Sum NEXT, PSNEXT @ Remote
Power Sum ACR, PSACR @ Remote

Display

3.7 in (9.4 cm) diagonal, 240 dots wide by 320 dots high, passive color, transmissive LCD with backlight.

Input Protection

Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage.

Case

High impact plastic with shock absorbing over-mold

Dimensions

Main unit and Smart Remote: 8.5 in x 4.4 in x 2.4 in (21.6 cm x 11.2 cm x 6cm), nominal

Weight

2.4 lb (1.1 kg), nominal (without adapter or module)

Operating Temperature

32°F to 104°F (0°C to 40°C)

Storage Temperature

-4°F to +140°F (-20°C to +60°C)

Operating relative humidity (% RH without condensation)

32°F to 95 °F (0°C to 35°C): 0 % to 90 % 95°F to 113°F (35°C to 45°C): 0 % to 70 %

Vibration

Random, 2 g, 5 Hz -500 Hz

Shock

1 m drop test with and without module and adapter attached

Safety

CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition + Amendments 1, 2

Pollution degree

Pollution Degree 2 as defined in IEC 60664 and applied to IEC 60950 "Safety of Information Technology Equipment, 1999"

Altitude

Operating: 4000 m; Storage: 12000 m

EMC

EN 61326-1

Power

Main unit and remote: Lithium-ion battery pack, 7.4 V, 4000 mAh

Typical battery life: 12 to 14 hours

Charge time (with tester off): 4 hours (below 40 °C)

AC adapter/charger, USA version: Linear power supply; Input 108 V ac to 132 V ac, 60 Hz ; Output 15 V dc, 1.2 A

AC adapter/charger, international version: Switching power supply; Input 90 V ac to 264 V ac, 48 to 62 Hz; Output 15 V dc, 1.2 A (isolated output)

Memory backup power in main unit: Lithium battery

Typical life of lithium battery: 5 years
The battery will not charge at temperatures outside of 0°C to 45°C (32°F to 113°F). The battery charges at a reduced rate between 40°C and 45°C (104°F and 113°F).

 

Calibration

Service center calibration period is 1 year

Performance Specifications

Note: all specifications for tests on twisted-pair cabling apply to 100 Ω cable. Contact Fluke Networks for information on measurement performance for cable with a different impedance.

Baseline accuracy

The baseline accuracy of all DTX Series testers meets or exceeds the requirements of Level IV as in draft 2nd Edition of IEC 61935-1 over the frequency range supported by the tester.

Category 6/Class E link test modes (and lower link categories)

DTX CableAnalyzer far exceeds Level III requirements of TIA/EIA-568-B.2-2 and IEC 61935-1

Class F link test modes

DTX-1800 is compliant with Level IV requirements as in the draft 2nd edition of IEC 61935-1.

Length for Twisted Pair Cabling

(Length specs do not include the uncertainty of the cable's NVP Value)

Parameter

Single-ended Test
Dual-ended Test (Main and Remote)

Range

800 m (2600 ft) - Single-ended Test
150 m (490 ft) - Dual-ended Test (Main and Remote)

Resolution

0.1 m or 1 ft - Single-ended Test
0.1 m or 1 ft - Dual-ended Test (Main and Remote)

Accuracy

± (1m + 4%) - Single-ended Test
± (1m + 4%) - Dual-ended Test (Main and Remote)

Delay Skew

 

Parameter

Twisted Pair Cabling

Range

0 ns to 100 ns

Resolution

1ns

Accuracy

± 10 ns

DC Loop Resistance Test

 

Parameter

Twisted Pair Cabling

Range

                O Ω  to 53Ω

                Resolution

0.1 Ω

Accuracy

± (1 Ω + 1%)

Overload Recovery Time

Less than 10 minutes to rated accuracy following over-voltage. Referencing is required after repeated or prolonged over-voltage.

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E