»  Categories   »      Auto Waveform Generator   »    Generator   »    Automotive   »    EMC / EMI   »    Automotive EMC  

image enlarge

EM TEST VDS 200N Series Voltage Drop Simulator & DC Voltage Source

Description

The VDS 200N series is used to simulate the various battery supply waveforms recommended by international standards and by car manufacturer requirements. Especially the manufacturer requirements are an important area covered by the VDS 200N series as there is a large variety of requirements. Secondly, the VDS 200N series serve as powerful DC voltage supplies for the DUT during the tests with automotive transients. The VDS 200N series covers all three supply voltage categories. Their current capability ranges up to 200A depending on the model and your application.

The VDS 200N is specifically designed to cope with almost every requirement of international and national as well as car manufacturer standards world-wide. Its integrated DC amplifier with a frequency range up to 50 kHz allows generating dips and drops, short interruptions and many kind of voltage variation representing various phenomena being measured on a wiring harness.

The VDS 200N30.1 and VDS 200N50.1 models are bipolar amplifiers able to absorb energy fed back from the DUT up to nominal current.

The VDS 200N offers the QuickStart with parameters being adjustable during test to evaluate the susceptibility level of a DUT. Pulse 4 and 2b as per ISO 7637-2:2004 and many more car manufacturer specific waveforms are pre-programmed. Together with an external signal generator (e.g. AutoWave) the VDS 200N can generate most complex waveforms.

Features

  • Voltage up to 60V
  • Current up to 200A (peak up to 1,000A)
  • Bipolar-amplifier models available
  • Low output impedance
  • Powerful DC voltage source
  • Pulses 4 and 2b (ISO 7637-2/ISO 16750-2)
  • Pre-programmed test routines to simulate various supply waveforms
  • Input for external signal generator to produce most complex waveforms
  • Software for Windows Vista & Windows 7
  • USB and GPIB interfaces

Specifications

AVAILABLE VDS 200N-MODELS

VDS 200N10

Voltage Drop Simulator, 60V/10A

VDS 200N15

Voltage Drop Simulator, 60V/15A

VDS 200N30

Voltage Drop Simulator, 60V/30A

VDS 200N30.1

Bipolar Voltage Drop Simulator,

60V/30A and 30V/50A

VDS 200N50

Voltage Drop Simulator, 60V/50A

VDS 200N50.1

Bipolar Voltage Drop Simulator,

60V/50A and 30V/85A

VDS 200N100

Voltage Drop Simulator, 60V/100A

VDS 200N150

Voltage Drop Simulator, 60V/150A

VDS 200N200

Voltage Drop Simulator, 60V/200A

GENERAL

Source impedance

Zi = <10mohm

Voltage deviation

<1V with resistive load (including inrush current) recovering 63% of its maximum excursion within 100us

Ripple voltage

Ur <0.2Vp-p, frequency min. 400Hz

Sinusoidal signal capability vs. Frequency *)

Vpp max. 16V up to 20kHz

Vpp max. 10V up to 30kHz

Vpp max. 6V up to 50kHz

*)

Vpp max. 3V up to 100kHz via Analog In, controlled by

AutoWave/AMP 200Nx only

*)

VDS 200N30.1 and VDS 200N50.1:

Vpp max. 65V resp. 35V up to 50kHz with respect to the selected voltage range

Vpp max. 3V up to 100kHz via

Analog In, controlled by

AutoWave/AMP 200Nx only

Fuses

Depending on VDS 200N model

TEST ROUTINES FOR ARBITRARY WAVES

DC source

Max. 60V; current depending on VDS 200N model

Functions

Sine Wave Sweep

Sine Wave (Cranking)

Clipped Load Dump

Jump Start

Extern

GM 9105P Pulse 4

Drop and Jump pulse

Standard Test routines

ISO 7637, Pulses 2b and 4

ISO 16750-2

Jaso Test 1

Service

Service, Setup, Self test

INTERFACE

 

Serial interface

USB

Parallel interface

IEEE 488, addresses 1 - 30

Remote control

To connect an external signal

generator (10kohm):

0-10V / 0-50kHz

Max. 0.5V(p-p) / 0-100kHz

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E