EM TEST TSS 500N6B Telecom Surge Generator per Bellcore/Telcordia

Description

Telecommunication networks are exposed to lightning events. Therefore telecommunications equipment being connected to the outside world need to have appropriate protection to show an acceptable immunity to surge transients in order not to fail in case of lightning events. The TSS 500N6B is used for 4-wire applications as per Bellcore GR-1089-Core and supports 12 pair telecom port testing via the CNB 500 optional coupler. It can also be used for the 2-wire telecom port testing.

Telecom Surge Simulators of the TSS 500N series are used to proof the immunity of telecommunications equipment. The TSS 500N6B has been developed to represent an easy-to-use test equipment for testing 4-wire applications as per Bellcore GR-1089-Core. This standard includes several test pulses with different source impedance values to generate the pulses required by Bellcore for First Level Lightning and Intra-Building Lightning Surge tests as well as for AC power port testing. All test pulses are generated by means of a single tester.

The necessary CDN to connect the telecom ports (both for 2-wire and 4-wire applications) is integrated. The internal switching circuit automatically sets the generator to apply the test pulses according to the selected coupling mode. The TSS 500N6B also supports testing of 12 pair telecom ports simultaneously with the test pulse 10/360µs using the optional CNB 500.

Pre-programmed Standard Test routines allow highest user convenience. Still the TSS 500N6B offers the Quick Start test routine where parameters can be changed on-line during the test to evaluate the susceptibility level of an individual DUT.

Features

  • Compact Tester for Bellcore/Telcordia GR-1089-CORE
  • Test pulses for 4-wire telecom applications
  • Also covers 2-wire telecom port testing
  • Generates test pulses 10/360µs, 10/1,000µs and 2/10µs
  • Includes all necessary matching resistors
  • Built-in coupling network
  • Supports testing 12 pairs (10/360µs)
  • Manual operation
  • Standard Test routines
  • USB and GPIB interface

Specifications

FIRST LEVEL LIGHTNING FOR 4-WIRE PORTS, PULSE 10/1,000US (600V)

Voltage (o.c.)

50V - 600V -0/+15%, positive/negative

Current (s.c.)

8A - 100A per wire

Rise time

10μs +0us/-4μs

Pulse duration

1,000μs +500μs/-0μs

Repetition rate

1 pulse every 36s at 600V/100A per wire

FIRST LEVEL LIGHTNING FOR 4-WIRE PORTS, PULSE 10/1,000US (1,000V)

Voltage (o.c.)

50V - 1,000V -0/+15%, positive/negative

Current (s.c)

5A - 100A per wire

Rise time

10μs +0μs/-4μs

Pulse duration

1,000μs +500μs/-0μs

Repetition rate

1 pulse every 60s at 1,000V

FIRST LEVEL LIGHTNING FOR 4-WIRE PORTS, PULSE 10/360US (1,000V)

Voltage (o.c.)

50V - 1,000V -0/+15%, positive/negative

Current (s.c.)

5A - 100A per wire

Rise time

10μs +0μs/-2.5μs

Pulse duration

360μs +108μs/-0μs

Repetition time

1 pulse every 20s at 1,000V

FIRST LEVEL LIGHTNING FOR 4-WIRE PORTS, PULSE 2/10US (2,500V)

Voltage (o.c.)

100V - 2,500V -0/+20%, positive/negative

Current (s.c)

20A - 500A per wire

Rise time

2μs +0μs/-1μs

Pulse duration

10μs +7μs/-0μs

Repetition rate

1 pulse every 5s at 2,500V

INTRA BUILDING LIGHTNING FOR 4-WIRE PORTS, PULSE 2/10US (800V)

Voltage (o.c.)

100V - 800V -0/+20%, positive/negative

Current (s.c.)

12.5A - 100A per wire

Rise time

2μs +0μs/-1μs

Pulse duration

10μs +7μs/-0μs

Repetition rate

1 pulse every 2s at 800V/100A per wire

INTRA BUILDING LIGHTNING FOR 4-WIRE PORTS, PULSE 2/10US (1,500V)

Voltage (o.c.)

100V - 1,500V -0/+20%, positive/negative

Current (s.c.)

6A - 100A per wire

Rise time

2μs +0μs/-1μs

Pulse duration

10μs +7μs/-0μs

Repetition rate

1 pulse every 3s at 1,500V/100A per wire

SECOND LEVEL LIGHTNING FOR 4-WIRE PORTS, PULSE 2/10US (5,000V)

Voltage (o.c.)

100V - 5,000V -0/+20% positive/negative

Current (s.c.)

10A - 500A per wire

Rise time

2μs +0μs/-1μs

Pulse duration

10μs +7μs/-0μs

Repetition rate

1 pulse every 10s at 5,000V

INTERFACE

Serial interface

USB

Parallel interface

IEEE 488, addresses 1 – 30

GENERAL DATA

Dimensions

19"/9HU

Weight

approx. 45kg

Supply voltage

115/230V +10/-15%

Fuses

2xT2AT (230V) or 2xT4AT (115V)

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E