»  Categories   »      Programmable Supply   »    Single Phase Power   »    DC Power Supply   »    AC Power Supply   »    Power Supply   »    Mains Dips & Drops   »    Harmonics & Flicker   »    Dips & Interrupts   »    EMC / EMI  

image enlarge

EM TEST NETWAVE Series (1 Phase) Multifunctional AC/DC Power Sources

Description

The NetWave series (1-phase) are single phase AC/DC power sources, specifically designed to meet the requirements as per the standards IEC/EN 61000-4-13, -4-14 and -4-28. Used as a DC power source it covers the requirements as per the standards IEC/EN 61000-4-17 (Ripple on DC) and IEC/EN 61000-4-29 for voltage dips and interruptions on DC supplies.

With its low distortion and high stability, even if supplying dynamic loads, the NetWave series guarantees full compliant measurements for harmonics and flicker testing as per IEC/EN 61000-3-2,-3-3, -3-11 and -3-12 as well as JIS C 61000-3-2.
The NetWave series is well suited for testing inverters (e.g. solar power, wind power) and e-vehicles.

Additionally, the NetWave series (1-phase) offers the necessary capabilities for avionics testing as per DO-160, Airbus ABD0100 and Boeing as well as per MIL-STD-704.

The programmable AC and DC power source with its wide frequency bandwidth offers powerful waveform generation capabilities for various test applications in the EMC area and for avionics testing. Based on a Dual-Processor technology, with an integrated high-performance PC, a digital signal processor (DSP) and equipped with a hard disk the NetWave is capable to generate and record waveforms in real-time.

Its output power with low distortion and high stability, even if supplying dynamic loads, guarantees full compliant measurements for harmonics and flicker testing as per IEC/EN 61000-3-2, JIS C 61000-3-2 and IEC/EN 61000-3-3 as well as per IEC/EN 61000-3-11 and IEC/EN 61000-3-12. The NetWave is well suited for testing inverters of solar and wind power generators and e-vehicles. Additionally, the NetWave offers full capabilities for avionics testing as per DO-160, Airbus ABD0100 and Boeing as well as per MIL-STD-704.

According to standard requirements a pure sinusoidal voltage is needed for harmonics and flicker measurements. The output voltage of the NetWave is therefore guaranteed to have a very low distortion (THD) of less than 0.1% regardless of the load.

No matter whether waveforms are programmed of segments or of single points (normally resulting in MBs of data) the NetWave will do. Recording of waveforms with up to 1GByte is easily possible. The measuring channels are designed to handle up to +/- 500Vpeak and +/-150Apeak with 16bit resolution. Interfaces like GPIB, Ethernet and USB (to connect a memory stick) are common features with the NetWave.

Features

  • Wide Power Bandwidth; DC - 5kHz
  • Output Power up to 7,500VA AC and 9,000W DC
  • Output Voltage max. 360V AC and +/- 500V DC
  • High Inrush Current Capability up to 200A
  • Extended trigger and control capabilities (NetWave 7.3)
  • Built-in Arbitrary Waveform Generator for easy generation of complex waveforms
  • Standard Test Routines for IEC/EN requirements as well as for Aircraft and MIL-STD testing
  • Built-in voltage and current measurement (option)
  • Multiple Interfaces

Specifications

1-PHASE NETWAVE-MODELS

NetWave 3

Multifunctional AC/DC source, 3,500VA AC / 4,500W DC

NetWave 7

Multifunctional AC/DC source, 7,500VA AC / 9,000W DC

NetWave 7.x

Multifunctional AC/DC source, 7,500VA AC / 9,000W DC, with built-in isolation transformer required to perform tests as per aircraft (DO-160, Airbus and Boeing) and military (MIL-STD-704) standards

SPECIFICATIONS

Output frequency

Output frequency DC - 5,000Hz

Frequency accuracy, stability

100ppm

DC offset with AC signal

<20mV with linear load

Slew rate

8V/us

REGULATION

Voltage sense

Internal or external, 4 wires

Distortion (THD)

Less than 0.5%, @50/60Hz

Output voltage stability

Better than 0.1%

Output voltage accuracy

Better than 0.5%

Max. compensable drop on wire

5% f.s.

Current limiter

2A to Imax for f < 75Hz (NetWave 3)

5A to Imax for f < 75Hz (NetWave 7.x)

Protection

Over current, over voltage,

over temperature, low voltage

OUTPUTS

DUT connection

4mm safety lab connectors

DUT adapter with connector

(depends on country of use)

DISPLAY AND CONTROLS

Display

2-Line LCD, 40 characters

LED indicators

Power On

Active output channel

Trigger

Functional status hard disk

Operation

6 function keys,

Test On key: ON/OFF key for the

power source

INTERFACES

GPIB, Ethernet

USB (for memory stick)

RS 232 (input from DPA analyzer)

Frame bus (internal system bus)

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E