»  Categories   »      Harmonics & Flicker   »    EMC / EMI   »    Power Quality Analyzer   »    Analyzer  

image enlarge

EM TEST DPA 503N Digital Power Analyzer Harmonics & Flicker Test

Description

Harmonics and interharmonics are caused by modern electronic power conditioning modules. Such, mostly non-linear, modules to control loads and to reduce power consumption is the source of voltage at unwanted frequencies superposed on the supply voltage.

Voltage fluctuations caused by varying load currents may influence luminance or spectral distribution of lighting systems. The impression of unsteadies of visual sensation induced by this light stimulus is called flicker. The DPA 503N is used for 3-phase applications but also supports single phase applications.

The DPA 503N is a fully compliant analyzer for harmonics and flicker as per the latest IEC/EN 61000-3-2, IEC/EN 61000-3-3 and JIS C 61000-3-2 as well as IEC/EN 61000-3-11 and IEC/EN 61000-3-12:2011 requirements. The DPA 503N has six independent input channels; three for voltage and three for current. It follows the design specifications as per IEC/EN 61000-4-7:2002 and Am.1:2008 (for Class A instruments) for harmonics analyzers and IEC/EN 61000-4-15:2010 for flicker meters.

Based on a real-time kernel and equipped with its own hard disk it allows to record the measuring data continuously without any gaps or overlapping. The rectangular measurement window is synchronized to each group of 10 or 12 cycles of the mains supply frequency (50Hz or 60Hz) by means of a digital PLL (Phase Lock Loop). A wide-range current input (up to 140A) avoids loss of measured data due to range switching that would occur when using different shunt resistors.

The classification of the measurement can be selected at any time, before or after the measurement has been performed. During all measurements the AC supply voltage is measured simultaneously with the current.

Features

  • Real-time data acquisition
  • Internal hard disk for data storage
  • 16-Bit A/D converter
  • 6 input channels
  • Wide-range current input up to 140Arms
  • Wide-range voltage input up to 530Vrms
  • High-sophisticated analyzing capability
  • USB interface for control and data transfer

Specifications

MEASURING SYSTEM

Input channels 2

6 (3x current & 3x voltage)

Frequency range

15Hz - 3,000Hz

A/D converter

16 Bit

Controller

Embedded processor Pentium

200MHz

Signal processor

Motorola DSP

Memory

Internal hard disk

Category

Class I as per IEC/EN 61000-4-7

VOLTAGE INPUT

Input range

10V - 530V rms

Overload

4,000V peak

Accuracy

Better than 0.4% of reading

CURRENT INPUT

Input range external

Depending on CT model used.

Max. 140A with delivered CT

Accuracy external CT

Related to 16A

2 turns better than 0.8%

5 turns better than 0.6%

GENERAL DATA

Temperature

0°C - 40°C

Rel. humidity

10% - 90%, non-condensing

Power supply

85V - 255V, 47Hz - 63Hz

Power

Max. 50W

Dimension

19" 3HU: 133mm x 449mm x 500mm

Weight

12kg

Insulation

Input to case 3kV rms

Interface

USB for control and data transfer

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E