»  Categories   »      Magnetic Field Test   »    EMC / EMI   »    Generator   »    Continuous Wave Generator  

image enlarge

EM TEST CWS 500N3 Continuous Wave Simulator 10 Hz – 250 kHz

Description

The CWS 500N3 is the state-of-the-art solution in a compact single-box design to test the immunity to conducted low-frequency disturbances and low-frequency magnetic fields. The CWS 500N3 includes a LF signal generator and amplifier, a low-frequency transformer 2:1, a frequency- selective voltage/current meter and load resistors as required by the standards. For remote control via icd.control software both a GPIB and USB interface are available. icd.control software supports the test routines, controls external measuring devices and automatically generates a test report including all test data.

Key applications of the CWS 500N3 are in the automotive and aerospace area. Various international standards and MIL requirements call for magnetic field tests in the low frequency range. Apart from this the automotive industry requires conducted immunity tests with superposed sinusoidal signals on the DC supply voltage (ripple noise). For both applications the CWS 500N3 is the perfect equipment including everything in a single box, necessary for these tests.

The CWS 500N3 meets requirements of SAE J1113-2, ISO 11452-8, DO 160D/E Section 18 and MIL-STD-461 D/E CS101, CS109 and RS101.

Features

  • Most compact equipment for ripple noise on ac/dc supplies and magnetic fields
  • Built-in LF signal generator
  • Built-in LF amplifier
  • Built-in LF transformer 2:1
  • Built-in frequency-selective voltage and current meter
  • Built-in load resistors
  • Automatic self-calibration

Specifications

GENERAL OUTPUT CHARACTERISTICS (AMPLIFIER)

Frequency range

10Hz - 250kHz

Signal power

100W (nominal)

Signal level

0.001V - max. 7Vrms (14Vrms)

Signal current

Max. 15A rms

Harmonic distortion

> -20dBc at 100W power 0.5ohm

Current protection

Short circuit protected for current > 15A rms

Overvoltage protection

For voltages > 60V fed back by DUT

LF indicator

LED indicating the LF output status

LCD

Display of the test voltage and frequency

MEASUREMENTS

General

Frequency selective instrument for

Voltage Current and Magnetic field

Frequency

10Hz - 250kHz

Accuracy

Better than 5%

Current

Sense by 0.02ohm shunt.

1mA - 16A rms

Voltage

0.5mV - 12 V rms

Magnetic field

50ohm input for loop sensor

COUPLING TO BATTERY SUPPLY LINES

Transformer

Impedance ratio 1:4

Frequency range

 10Hz - 250kHz

DUT load

60VDC up to 30A

DUT load

300VAC up to 20A

Coupling capacitor

100uF/10uF to shunt the DC source

Output impedance

less than 0.5ohm at f<80kHz

GENERAL DATA

Dimensions

19"/6HU

Weight

approx. 36kg

Supply voltage

115V to 230V +10/-15%, 50/60Hz

Input power

Max. 600W

Power factor

cos (phi) = 0.96 at max. output power as per IEC 555

Fuses

2 x 6.3AT (115V) or 2 x 3.15AT (230V)

Cooling

Active cooling, air ventilation

Temperature

10°C to 40°C

Rel. humidity

Max. 85%, non condensing

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E