»  Categories   »      Automotive   »    EMC / EMI   »    Automotive EMC   »    Magnetic Field Test  

image enlarge

EM TEST AMP 200N Low Frequency Signal Source 0 Hz – 250 kHz 250W

Description

The AMP 200N has been designed as a low-frequency signal source to generate sinusoidal signals used to simulate ripple noise and ground shift noise as required by a variety of standards in the automotive industry e.g. as per Ford EMC-CS-2009.1, CI 210 and CI 250 as well as RI 150. The AMP 200N is controlled by the EM TEST Autowave to also allow the generation of non-sinusoidal and customized signals. Additionally, the AMP 200N can be used to generate magnetic fields by means of a radiation loop or small Helmholtz coils as per RI 140 of Ford EMC-CS-2009.1.

The AMP 200N unifies a low-frequency signal generator and a powerful amplifier module giving a maximum amplitude of 150V peak-to-peak as required e.g. by Ford EMC-CS-2009.1. It generates both sinusoidal and transient signals. Equipped with a DDS it generates any sinusoidal signal with a frequency up to 250kHz. The AMP 200N is controlled by the EM TEST Autowave in order to generate any sinusoidal or non-sinusoidal/transient signals and is therefore fully supported by the autowave.control software with its exhaustive library of pre-programmed standards and its outstanding reporting and documentation capabilities.

The AMP 200N can also be used for magnetic field testing using a Radiation Loop and Loop Sensor. Extended by the optional measuring module, the AMP 200N offers means for frequency-selective current measurement, voltage measurement and measurement of the magnetic field strength.

Features

  • Built-in DDS to generate sinusoidal signals up to 250kHz
  • Built-in LF amplifier, 250W
  • Output voltage max. 140V p-p, 50V rms
  • Output current max. 5A rms
  • Programmable DC voltage offset
  • Controlled by Autowave and autowave.control via Framebus
  • Integrated voltage measurement 10Hz - 250kHz (optional)
  • Integrated field strength measurement (optional)
  • Integrated frequency-selective current measurement 10Hz - 250kHz (optional)
  • Safety interlock

Specifications

AMPLIFIER OUTPUT CHARACTERISTICS

Frequency range

DC - 250kHz

Signal power

250W (nominal)

Output voltage

50Vrms, max. 140V(p-p) up to 200kHz

 

45Vrms 200kHz - 250kHz

Output current

Max. 5Arms up to 200kHz

 

Max. 4Arms 200kHz - 250kHz

Harmonic Distortion (THD)

< 0.1%

Protection

- Short circuit

- Overtemperature

SIGNAL GENERATOR OUTPUT CHARACTERISTIC (BUILT-IN)

Frequency range

DC, 10Hz - 250kHz (sinusoidal)

Output voltage

+/-10V

DC offset

0-10V, programmable, to control external DC amplifier

INTERFACE

Serial interface

Framebus to AutoWave or NetWave

GENERAL DATA

Dimensions

19", 3HU (500mm x 449mm x 133mm)

Weight

Approx. 18kg

Supply voltage

115V or 230V +10/-15%, 50/60Hz

Input power

Max. 500W

Fuses

2 x 6.3AT (115V) or 2 x 3.15AT

(230V)

Cooling

Active cooling, air ventilation

Temperature

10°C - 40°C

Rel. humidity

Max. 85%, non-condensing

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E