»  Categories   »      Single Phase Power   »    AC Power Supply   »    Power Supply  

image enlarge

Elgar CW 801M Continuous Wave Low Profile AC Source 800 VA

Description

The ContinuousWave (CW) Series of AC power sources provide clean single phase power at an impressive price/performance ratio. These compact switch mode sources come in two series, manual (CW-M) or programmable (CW-P) with standard IEEE-488.2 or RS-232 control. Both series have three power levels, 800 VA, 1250 VA and 2500 VA. The 800 and 1250 VA models are 2U (3.5") high and allow the unit under test to be connected to the front or rear panel. The 2500 VA model is 3U (5.25") high with rear panel output connections. All models can be operated in a benchtop or rackmount configuration.

The front panels have two bright four digits, seven segment displays. Power Factor Corrected (PFC) universal input voltage allows maximum power to be delivered from an AC outlet without the user selecting the range. Fully rated current is delivered for either output voltage range of 135 VAC or 270 VAC over a standard frequency range of 45 to 500 Hz. Both series can be paralleled to provide extra power. A separate output-on switch controls power to the load. Remote voltage sense is standard. Transformer coupled output is protected against overvoltage and overcurrent. The unit is also protected against over temperature conditions. A two-speed fan results in quieter operation at lower power levels. All models are CE marked.

Features

  • Wide range PFC Input
  • Low THD and AC noise
  • Advanced Measurement Available
  • Field Parallel Configurable
  • Multiple Units Configurable for Poly-Phase Operation
  • Power: 2500VA
  • Voltage: 0-135 Vrms, 0-270Vrms, user selectable
  • Current: 18.6 Arms, 9.3Arms

Elgar CW801M Applications

The ContinuousWave (CW) is designed for testing single or polyphase electronics. The CW is well suited for applications requiring a cost-effective low profile AC source.

Applications Include

  • Testing for real world sine wave power conditions
  • 400 Hz testing for avionics equipment
  • 50/60 Hz margin testing
  • Ballast testing
  • Components testing
  • Power supply testing for AC to DC converters

Specifications

Model

CW 801M

CW 1251M

CW 2501M

CW 801P

CW 1251 P

CW 2501P

Power

800 VA

1250 VA

2500 VA

90 - 264 VAC

1250 VA

2500 VA

Voltage

90 - 264 VAC

103 - 264 VAC

180 - 264 VAC

90 - 264 VAC

103 - 264 VAC

180 - 264 VAC

Current

13 ARMS max

18.5 ARMS max

19.5 ARMS max

13 ARMS max

18.5 ARMS max

19.5 ARMS max

Frequency

47 to 63 Hz

Phases

single-phase

Power Factor

>0.99 typical at full load nominal line

Efficiency

>73% typical at full load

Output

Model

CW801M

CW 1251M

CW 2501M

CW 801P

CW 1251P

CW 2501P

Power

800 VA

1250 VA

2500 VA

90 - 264 VAC

1250 VA

2500 VA

Voltage

Voltage ranges

0 to 135 Vrms, 0 to 270 Vrms, user selectable

Accuracy (>5VAC)

± 1% of range

±0.1% of range <100 Hz, ± 0.2% of range >100 Hz

Resolution

0.1 Vrms

Total harmonic distortion

0.25% typical <100Hz add 0.5%/100 Hz above 100 Hz

AC noise level (typical)

<50 VRMS

<50 VRMS

<100 VRMS

<50 VRMS

<50 VRMS

<100 RMS

Amplitude stability¹

±0.1% of full scale

±0.05% of full scale

Load regulation

±0.1% of full scale voltage for a full resistive load to no load (<10 mVRMS typical, measured at point of sense)

Line regulation

±0.1% of full scale voltage for a ±10% line change from nominal line voltage (<5 mVRMS typical, measured at point of sense)

Remote voltage sense

5 Vrms total lead voltage drop

Current

135VAC Range

6.0 ARMS

9.4 ARMS

18.6 ARMS

6.0 ARMS

9.4 ARMS

18.6 ARMS

270VAC Range

3.0 ARMS

4.7 ARMS

9.3 ARMS

3.0 ARMS

4.7 ARMS

9.3 ARMS

Accuracy

± 0.5% typical

± 0.5% max

Resolution

0.1 ARMS

0.01 ARMS

Frequency range

Range

45 to 500 Hz

45 to 500 Hz, 45 to 1000 Hz (option)

Accuracy

±0.5% typical

±0.02% max

Resolution

0.1 Hz

0.1 Hz, 0.01 Hz for remote programming

Phase

All models single phase output. Multi-phase system configuration with Digital Expansion Cable

Power factor of load

0 lag to 0 lead

Physical

Model

CW 801M

CW 1251M

CW 2501M

CW 801P

CW 251P

CW 2501P

Height

3.5 in.

3.5 in.

5.25 in.

3.5 in.

3.5 in.

5.25 in.

Width

19 in.

19 in.

19 in.

19 in.

19 in.

19 in.

Depth

20.07 in.

20.07 in.

20.07 in.

20.07 in.

20.07 in.

20.07 in.

Weight

48 lbs (22 kg)

53 lbs (24 kg)

86 lbs (39 kg)

48 lbs (22 kg)

53 lbs (24 kg)

86 lbs (39 kg)

Shipping Weight

56 lbs (25 kg)

61 lbs (28 kg)

94 lbs (43 kg)

56 lbs (25 kg)

61 lbs (28 kg)

94 lbs (43 kg)

Environmental

Operating Temperature

0 to 40°C

Storage Temperature

-40 to +70°C

Humidity Range

0 to 85% at 25°C derate to 50% at 40°C (non condensing)

Altitude

Operating full power available up to 6,000 feet, non operating to 40,000 feet

Cooling

Dual fan speed with side air intake, exhaust to rear

General

Regulatory compliance

CE Mark

Measurements

Model

CW 801M

CW 1251M

CW 2501M

CW 801P

CW 1251P

CW 2501P

Power

800 VA

1250 VA

2500 VA

90 - 264 VAC

1250 VA

2500 VA

Voltage

Range

0 to 270 Vrms

0 to 270 Vrms, 0 to 310VRMS (option)

Accuracy² (VAC >5V)

± 1% of full range

±0.1% of range <100 Hz, ± 0.2% of range>100 Hz,
± 0.3% of range>500 Hz (option)

Resolution

0.1 Vrms

0.1 Vrms

Current³

Range

6.0 ARMS

9.4 ARMS

18.6 ARMS

0 - 6.0 ARMS

0 - 9.4 ARMS

0-18.6 ARMS

Accuracy

±2% of range for linear loads with current >0.2A,
> 0.4A for 2500 VA

±0.5% of range for linear loads

Resolution

0.1 ARMS

0.01 ARMS

Current³

Range

-

-

-

0 to 25 A

0 to 35 A

0 to 70 A

Accuracy

-

-

-

±1% of range

Resolution

-

-

-

0.1 A

Frequency

Range

45 to 500 Hz

45 to 500 Hz, 45 to 1000 Hz (option)

Accuracy

±0.5% typical

±0.02% max

Resolution of display

0.1 Hz

0.1 Hz

Measurements

Model

CW 801MCW 1251M

CW 2501MCW 801P

CW 1251 PCW 2501 P

Power

800 VA

1250 VA

2500 VA

Power³

Range

0 - 800 W

0 - 1250 W

0 - 2500 W

Accuracy

±2% of range for linear loads

Resolution

1 W

Apparent Power³

Range

0 to 800 VA

0 to 1250 VA

0 to 2500 VA

Accuracy

±2% of range for linear loads

Resolution

1 VA

Power Factor³

Range

0 to 1

Accuracy

±4% of range for linear loads

Resolution

0.01

Crest Factor

Range

0 to 3.5

Accuracy

±5% of range

Resolution

0.01

Phase

Range

-359 to +359 degrees. Positive indicates time lag from reference

Accuracy

Within 100 microseconds of equivalent angle

Resolution

1         degree

Note:

1*  Over 8 hours at constant line, load and temperature after 15-minute warm-up typical

2*  Typical values measured at point of sense

 3* In a parallel system (for programmable units only), the current/power displayed on the master unit is the sum of all units in the system

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E