»  Categories   »      EMC / EMI   »    RF Amplifier   »    Low Power Amplifier   »    Low Frequency Amplifier   »    Broadband Amplifier   »    Amplifier  

image enlarge

Com-Power ACS-181 Power Amplifier 150 kHz – 80 MHz 100W

Description

The ACS-181 is part of Com-Power's series of broadband RF amplifiers; diverse in application, yet specifically geared for use in EMC immunity testing applications. The ACS-181model was engineered to provide high gain, with excellent efficiency and reliability, at an unbeatable price. It is the perfect amplifier solution for IEC 61000-4-6 Conducted Immunity testing (150 kHz to 80 MHz), complementing Com-Power's full line of Coupling/Decoupling Networks (CDN's) and related test and calibration accessories. With its 50 dB gain, 100 Watt nominal power output, it easily achieves 3 Vrms or 10 Vrms test levels with any compliant coupling network (CDN, EM Clamp, Injection Probe, etc.) The ACS-181 amplifier complies with all required technical specifications for IEC 61000-4-6 compliance testing, yet its low cost makes it affordable even as part of a pre-compliance testing solution.

Features

  • Immunity Testing
  • IEC 61000-4-6
  • 100 Watts

Specifications

Specifications:

 

Frequency Range

150 kHz to 80 MHz

Rated Power Output

100 watts into 2:1 VSWR

Gain 

50 dB ±2 dB

Input for rated output 

0 dBm (typical)

Automatic Safety Shut-off

125 watts ± 2

Power Output @ 1 dB Compression Point

N/A

Input:

 

Impedance 

50 ohms (nominal)

VSWR

1.7 (maximum)

Input Signal Modulation Compatibility:

AM, FM, or Pulse modulation

Connector

Type N on Front Panel 

Output:

 

Impedance    

50 ohms (nominal)

VSWR  

1.7 (maximum)

Harmonic distortion 

-15 dBc at 75 watts

Mismatch Tolerance

Automatic Safety Shut-off @ VSWR >5

Connector   

Type N on Front Panel

Power

(Universal)

AC, Single Phase

100-240 VAC 50/60 Hz

Display and Interfaces:  

USB Remote Interface

Front Panel Display (Column 1)

Amplifier Current measurement Data

Front Panel Display (Column 2)

Amplifier Temperature measurement data

Front Panel Display (Column 3)

Load VSWR, RF Power Input/Output, Gain

Remote Interlock (optional) 

2-pin DIN

Mechanical:

 

Cooling 

Forced air (self-contained fans)

Size

19” Rack 4U

Weight 

50 lbs (22.6 kg)

Operating Temperature Range

0° C to +40° C

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E