»  Categories   »      Industrial Oven   »    Environmental   »    Chamber / Oven  

image enlarge

Blue M 146 Series Standard Oven 15°C above ambient to 350°C

Description

Mechanical Convection Standard Oven

The Blue M Standard Mechanical Convection Oven is ideal for a number of industrial oven applications, including ASTM testing, epoxy curing, moisture drying, UL testing, aging of electronic components and devices, and other processes and testing requirements.

Features

  • High quality design and simple operation - lower total cost of ownership
  • Horizontal airflow ensures uniform thermal performance under all loading conditions
  • Differential air pressure switches alert operators before costly problems with batch runs
  • Many different workspaces sizes to fit virtually any requirement
  • Quick access for simple inner chamber cleaning
  • Easy to use controller for repeatable results and less training requirements
  • Heavy gauge steel exterior for long lasting performance
  • Reinforced 304 stainless steel interior resists corrosion and makes cleaning easy
  • 4 inches of fiberglass insulation saves energy and provide cool to the touch exterior
  • 3-inch diameter lead-in port allows for easy instrument pass-through
  • Adjustable air intake and exhaust dampers for flexible testing conditions
  • Exclusive Blue M Eterna heating elements for extreme reliability and life
  • Infinitely variable control from full recirculation to full one pass to accommodate any processing need
  • Profiling or single Setpoint temperature controls offer flexible recipe options
  • High-volume air delivery via a multi-blade centrifugal blower

Standard Safety Features

  • Overtemperature protection
  • Safety airflow switch shuts off power to heater if no airflow 

Controller - Watlow EZ Zone PM (PID)

  • Single channel ¼ DIN non-profiling type controller
  • Type J thermocouple for temperature measurement
  • Fully programmable menu system
  • Auto Tune is provided for fast, efficient start ups
  • EZ-Zone® configuration software is provided on a CD
  • Watlow standard bus communications is provided for the EZ-Zone configuration software only

Specifications

Condensed Specification

Model

DC-146 (Bench model)

DC-206 (Bench model)

DC-256 (Bench model)

DC-296 (Floor model)

DC-136 (Floor model)

DC-336 (Floor model)

DC-1406 (Floor model)

DC-1506 (Floor model)

Interior Volume

1.6 cu. ft.

4.2 cu. ft.

5.8 cu. ft.

9 cu. ft.

11.0 cu. ft.

11.0 cu. ft.

24.0 cu. ft.

20.0 cu. ft.

Interior Dimensions W x D x H in(mm)

14 x 14 x 14 (356 x 356 x 356)

20 x 18 x 20 (508 x 457 x 508)

25 x 20 x 20 (635 x 508 x 508)

25 x 25 x 25 (635 x 635 x 635)

38 x 20 x 25 (965 x 508 x 635)

25 x 20 x 38 (635 x 508 x 965)

48 x 24 x 36 (940 x 635 x 940)

37 x 25 x 37 (940 x 635 x 940)

Exterior Dimensions W x D x H in(mm)

34 x 30 x 43 (864 x 762 x 1092)

40 x 34 x 49 (1016 x 864 x 1295)

45 x 36 x 49 (1143 x 914 x 1245)

50 x 36 x 74 (1270 x 914 x 1880)

58 x 36 x 62 (1473 x 914 x 1575)

45 x 36 x 75 (1143 x 914 x 1905)

68 x 40 x 73 (1727 x 1016 x 1854)

58 x 42 x 75 (1473 x 1067 x 1905)

Machine Footprint

7.1 sq. ft.

9.4 sq. ft.

11.0 sq. ft.

11.0 sq. ft.

15.0 sq. ft.

11.0 sq. ft.

19.0 sq. ft.

17.0 sq. ft.

 

Electrical Service

Model

DC-146 (Bench model)

DC-206 (Bench model)

DC-256 (Bench model)

DC-296 (Floor model)

DC-136 (Floor model)

DC-336 (Floor model)

DC-1406 (Floor model)

DC-1506 (Floor model)

208 VAC 1 Ph 50/60 Hz Line current (per ph)

2.2 kW 14

3.0 kW 17

4.2 kW 25

6.0 kW 33

6.0 kW 33

6.0 kW 33

6.8 kW 38

6.8 kW 38

240 VAC 1 Ph 50/60 Hz Line current (per ph)

3.0 kW 16

4.0 kW 20

6.0 kW 29

8.0 kW 35

8.0 kW 35

8.0 kW 35

9.0 kW 44

9.0 kW 44

208 VAC 3 Ph 50/60 Hz Line current (per ph)

N/A

6.8 kW 20

9.0 kW 27

13.5 kW 40

13.5 kW 40

13.5 kW 40

18.0 kW 53

18.0 kW 53

240 VAC 3 Ph 50/60 Hz Line current (per ph)

N/A

9.0 kW 23

12.0 kW 31

18.0 kW 46

18.0 kW 46

18.0 kW 46

24.0 kW 61

24.0 kW 61

480 VAC 3 Ph 50/60 Hz Line current (per ph)

N/A

9.0 kW 12

12.0 kW 16

18.0 kW 23

18.0kW 23

18.0kW 23

24.0kW 31

24.0kW 31

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E