»  Categories   »      TWT Amplifier   »    Mid-Power Amplifier   »    Microwave Amplifier   »    High Frequency Amplifier   »    Broadband Amplifier   »    Amplifier  

image enlarge

Amplifier Research 250T8G18 TWT Amplifier 7.5 GHz – 18 GHz 250W

Description

Amplifier Research 250T8G18 is a self contained, forced air cooled, broadband traveling wave tube (TWT) microwave amplifier designed for applications where instantaneous bandwidth and high gain are required. A reliable TWT provides a conservative 250 watts minimum at the amplifier output flange. Stated power specifications are at the fundamental frequency.

The amplifier's front panel digital display shows forward and reflected output plus extensive system status information accessed through a series of menus via soft keys. Status indicators include power on, warm-up, standby, operate, faults, excess reflected power warning and remote.

Standard features include a built-in IEEE- 488 (GPIB) interface, 0 dBm input, VSWR protection, gain control, RF output sample port, auto sleep, plus monitoring of TWT helix current, cathode voltage, collector voltage, external video pulsing, heater current, heater voltage, baseplate temperature and cabinet temperature.

Modular design of the power supply and RF components allow for easy access and repair. Use of a switching mode power supply results in significant weight reduction. The external video pulsing feature reduces prime power use for pulse applications.

Housed in a stylish contemporary cabinet, this unit is designed for bench top use, but can be removed from the cabinet for rack mounting.

The Model 250T8G18 provides readily available RF power for a variety of applications in Test and Measurement, (including EMC RF susceptibility testing), Industrial and University Research and Development, and Service applications.

Features

  • Broadband
  • Forced air cooled
  • Digital display
  • AM, FM or pulse modulation
  • IEEE-488 (GPIB) interface
  • VSWR protection
  • Gain control
  • 0 dBm input
  • RF output Sample ports
  • Auto sleep

Specifications

POWER (fundamental), CW, @ OUTPUT FLANGE

Nominal

300 watts

Minimum

250 watts

Linear @ 1dB Compression

70 watts minimum

FLATNESS

±12 dB maximum, equalized for ±5 dB maximum rated power

FREQUENCY RESPONSE

7.5-18 GHz instantaneously

INPUT FOR RATED OUTPUT

1.0 milliwatt maximum

GAIN (at maximum setting)

54 dB minimum

GAIN ADJUSTMENT (continuous range)

35 dB minimum

INPUT IMPEDANCE

50 ohms, VSWR 2.0:1 maximum

OUTPUT IMPEDANCE

50 ohms, VSWR 2.5:1 typical

MISMATCH TOLERANCE

Output power foldback protection at reflected power exceeding 50 watts. Will operate without damage or oscillation with any magnitude and phase of source and load impedance. May oscillate with unshielded open due to coupling to input. Should not be tested with connector off.

MODULATION CAPABILITY

Will faithfully reproduce AM, FM, or pulse modulation appearing on the input signal. AM peak envelope power limited to specified power.

VIDEO PULSE CAPABILITY

Pulse Width:

0.05 microseconds min

Pulse Rate (PRF):

100 kHz max

RF Rise and Fall:

30 ns max (10% to 90%)

Delay:

300 ns max from pulse input to RF 90%

Pulse width distortion:

±30 ns max (50% points of output pulse width compared to 50% points of input pulse width)

NOISE POWER DENSITY

Pulse On

Minus 70 dBm/Hz (maximum)

Minus 72 dBm/Hz (typical)

Pulse off

Minus 140 dBm/Hz (typical)

HARMONIC DISTORTION

Below 10 GHz, minus 5 dBc max., minus 7 dBc typ.

10-12 GHz, minus 8 dBc max., minus 12 dBc typ.

Above 12 GHz, minus 20 dBc max., minus 30 dBc typ.

PRIMARY POWER

190-260 VAC

50/60 Hz single phase

2.5 kVA maximum

CONNECTORS

RF input

Type N female on rear panel

RF output

TypeWRD-750D24 waveguide flange on rear panel

RF output sample port

Type N female on rear panel

GPIB

IEEE-488 (f) on rear panel

Interlock

DB-15 female on rear panel

Video

BNC female on rear panel

COOLING

Forced air (self contained fans), air entry and exit in rear.

SIZE (W x H x D)

50.3 x 29.7 x 68.6 cm, 19.8 x 11.7 x 27 in.

WEIGHT (approximate)

53 kg, 115 lbs.

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E