»  Categories   »      EMI   »    Current Injection Probe   »    EMC / EMI  

image enlarge

A.H. Systems ICP-522 Current Injection Probe 10 kHz – 400 MHz

Description

Injection Current Probes are used to inductively couple large RF currents into conductors passing through their aperture. The conductors are signal, control and power circuits of equipment under test for conducted susceptibility or immunity. This injection current probe is used to couple large RF currents from 1 MHz to 400 MHz. The CW input power rating of this injection current probe is 200 watts for duration of 30 minutes.

Features

  • Measures currents on 50 Hz, 60 Hz and 400 Hz power lines
  • Individually Calibrated (Transfer Impedance calibration included)
  • Split Type Clamp-on Design

Specifications

Frequency Range

1 MHz - 400 MHz

Insertion Loss (dB)

4 to 22

Transfer Impedance (dBW)

12 to 33

Connector

N-Type, Female

 A.H. Systems ICP-522 Physical Dimensions

Aperture

1.6" (40 mm)

Diameter

5" (127 mm)

Weight

4.0 lb.'s (1.8 kg)

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E