EMC / EMI
Electromagnetic compatibility (EMC) is the branch of electrical sciences which studies the unintentional generation, propagation and reception of electromagnetic energy with reference to the unwanted effects (Electromagnetic interference, or EMI) that such energy may induce. EMC aims to ensure that equipment items or systems will not interfere with or prevent each other's correct operation through spurious emission and absorption of EMI. EMC is sometimes referred to as EMI Control, and in practice EMC and EMI are frequently referred to as a combined term "EMC/EMI".
|
|
| TESEQ KEMA 801 RF Attenuation Clamp | The KEMA 801 is recommended as an additional decoupling network (ferrite tube clamp) for immunity test according to IEC/EN 61000-4-6 when using the clamp injection method. It shall be inserted on all the cables between EUT and AE except the cable und... View Details >>
|
|
|
| TESEQ KEMZ 801 EM Clamp for IEC/EN 61000-4-6 | EC 61000-4-6 (EN 61000-4-6) defines three basic types of transducer used for the injection of test signals into the equipment under test (EUT). The basic requirement is to inject a known level of RF signal onto the cable of the EUT at each test frequ... View Details >>
|
|
|
|
| TESEQ LNA 6000 Low Noise Amplifier 1 MHz – 3 GHz | The LNA 6000 is a low noise amplifier with 12.5 dB of gain covering the nominal frequency range 1 MHz to 3 GHz and can be used in the range from 200 kHz to 4 GHz. With its high gain and low noise figure, it will significantly increase the sensitivity... View Details >>
|
|
|
|
| TESEQ LNA 6900 Low Noise Amplifier 9 kHz – 2 GHz | The LNA 6900 is a low noise amplifier with 25 dB of gain covering the nominal frequency range 9 kHz to 2 GHz and can be used up to 4 GHz. With its high gain and low noise figure, it will significantly increase the sensitivity of virtually all spectru... View Details >>
|
|
|
| TESEQ LNA 6901 Low Noise Amplifier 9 kHz – 1 GHz | The LNA 6901 is a low noise amplifier with typ. 28 dB of gain covering the nominal frequency range 9 kHz to 1 GHz and can be used up to 2 GHz. With its high gain and low noise figure, it will significantly increase the sensitivity of virtually all sp... View Details >>
|
|
|
| TESEQ MD 200 High Voltage Differential Probe | The Teseq MD 200 and MD 200A high voltage differential probes are ideally suited to allow EMC engineers to verify their conducted EMC test generators periodically. Their performance permits to be used for many other purposes where higher voltages hav... View Details >>
|
|
|
| TESEQ MD 200A High Voltage Differential Probe | The Teseq MD 200 and MD 200A high voltage differential probes are ideally suited to allow EMC engineers to verify their conducted EMC test generators periodically. Their performance permits to be used for many other purposes where higher voltages hav... View Details >>
|
|
|
| TESEQ MD 300 Surge Pulse Current Probe Set | The MD 300 probe has been specially designed to verify surge current pulses as specified in IEC/EN 61000-4-5, ANSI C62.41 and their derivates.
The main advantage of the MD 300 current probe is, that the measuring system is physically isolated from... View Details >>
|
|
|
|
| TESEQ NFPS 1 Near Field Probe Set | A diagnostic “tool kit” for use in both electrical and mechanical environments featuring three hand held probes (two magnetic, one electric) covering the frequency range 9 kHz to 1 GHz together with a 30 dB pre-amplifier, power adaptor and check ... View Details >>
|
|
|
|
|
|
|
|
|
|
| TESEQ PA 5740 Power Amplifier/Battery Simulator | This battery simulator is designed to replace the vehicle battery in the test environment. These sources must fulfill various criteria concerning power rating, voltage, slew rate, impedance, etc. depending on the particular application. Bipolar curre... View Details >>
|
|
|
| TESEQ PA 5840 Power Amplifier/Battery Simulator | This battery simulator is designed to replace the vehicle battery in the test environment. These sources must fulfill various criteria concerning power rating, voltage, slew rate, impedance, etc. depending on the particular application. Bi-polar curr... View Details >>
|
|
|
| TESEQ PMR 6006 Power Meter 1 MHz – 6 GHz | EMC immunity testing makes very specific demands on RF power meters. A large dynamic range, fast measurements, rugged design and a frequency range that matches the application are some of the unique requirements for power meters in an EMC test enviro... View Details >>
|
|
|
| TESEQ PMU 6003 Power Meter 9 kHz – 3 GHz | EMC immunity testing makes very specific demands on RF power meters. A large dynamic range, fast measurements, rugged design and a frequency range that matches the application are some of the unique requirements for power meters in an EMC test enviro... View Details >>
|
|
|
| TESEQ PMU 6006 Power Meter 1 MHz – 6 GHz | EMC immunity testing makes very specific demands on RF power meters. A large dynamic range, fast measurements, rugged design and a frequency range that matches the application are some of the unique requirements for power meters in an EMC test enviro... View Details >>
|
|
|
|
|
|
|